目的比较短声和短音诱导的SP—AP电位。方法20只豚鼠分为2组,每组10只,分别采用短声和短音刺激,用圆窗电极记录SP—AP复合波。结果两种刺激声都能较好地诱导出SP-AP复合波。在1、2、4、8kHz短音诱导的SP—AP波形较好,刺激声强度为100dBSPL时,各频率短音诱导的SP波振幅分别为-13.56±8.7、-16.61±10.53、-10.13±14.75、-3.714-14.49μv;短声诱导的SP波振幅为-4.44±10.81μv。结论短音能成功诱导出SPAP波,且具有频率特异性。
Objective To compare the characteristics of the SP-AP compound wave elicited by click and tone pip. Methods The electrocochleogram was recorded with round window electrode, and waves were elicited by click and tone pips, respectively. Results The SP-AP compound waves were elicited 1,2,3,4 and 8 kHz tone pip and click. The amplitude of SP at each frequency was -13. 56±8. 7, -16. 61±10. 53,-10. 13±14. 75, -3. 71±14.49,-2.99±5.4 and -4.44±10.81 μv, respectively. Conclusion Tone pip at 1,2,3, 4, 8 kHz can elicit SP, and produce frequency specific SP wave. This is helpful to identify the lesion site of auditory neuropathy.