目的验证本课题组研发的BurnCalc人体三维扫描系统在烧伤创面面积评估中的临床应用效果。方法2015年1—6月,笔者单位门诊共就诊符合人选标准的48例烧伤患者。对先就诊的12例患者,每例患者选取1个位于四肢或者躯干部位的创面,由3名主治医师分别使用BurnCalc人体三维扫描系统单独测量创面面积,进行系统稳定性测试。对后就诊的36例患者,每例患者选取1个创面,其中四肢、前躯干、侧躯干创面各12个,由同一名主治医师分别采用无菌薄膜勾边法、美国国立卫生研究院(NIH)ImageJ法、BurnCalc人体三维扫描系统测量创面面积。使用秒表记录3种测量方法分别获取36个创面信息所用时间。使用组内相关系数(ICC)评价测试者之间的稳定性,对数据行随机区组方差分析和Bonferroni检验。结果(1)3名医师使用BurnCalc人体三维扫描系统测量所得患者创面面积分别为(122±95)、(121±95)、(123±96)cm^2,总体比较,差异无统计学意义(F=1.55,P〉0.05)。3名医师之间的ICC为0.999。(2)无菌薄膜勾边法、NIHImageJ法、BurnCalc人体三维扫描系统测量所得患者四肢创面面积分别为(84±50)、(76±46)、(84±49)cm^2,无菌薄膜勾边法与BurnCalc人体三维扫描系统测量所得患者四肢创面面积比较,差异无统计学意义(P〉0.05);NIHImageJ法测量所得患者四肢创面面积小于无菌薄膜勾边法及BurnCalc人体三维扫描系统(P值均小于0.05)。无菌薄膜勾边法、NIHImageJ法、BurnCalc人体三维扫描系统测量所得患者前躯干创面面积总体比较,差异无统计学意义(F=0.33,P〉0.05)。无菌薄膜勾边法、NIHIm—ageJ法、BurnCalc人体三维扫描系统测量所得患者侧躯干创面面积分别为(169±88)、(150±80)、(169±86)cm^2,无菌薄膜勾边法与BurnCalc人体三维扫描系统测量所得患者侧躯?

英文摘要:

Objective To validate the clinical effect of three dimensional human body scanning system BurnCalc developed by our research team in the evaluation of burn wound area. Methods A total of 48 burn patients treated in the outpatient department of our unit from January to June 2015, conforming to the study criteria, were enrolled in. For the first 12 patients, one wound on the limbs or torso was selected from each patient. The stability of the system was tested by 3 attending physicians using three dimensional human body scanning system BurnCalc to measure the area of wounds individually. For the following 36 patients, one wound was selected from each patient, including 12 wounds on limbs, front torso, and side torso, respectively. The area of wounds was measured by the same attending physician using transparency tracing method, National Institutes of Health (NIH) Image J method, and three dimensional human body scanning system BurnCalc, respectively. The time for getting information of 36 wounds by three methods was recorded by stopwatch. The stability among the testers was evaluated by the intra-class correlation coefficient (ICC). Data were processed with randomized blocks analysis of variance and Bonferroni test. Results ( 1 ) Wound area of patients measured by three physicians using three dimensional human body scanning system BurnCalc was ( 122 ± 95 ) , ( 121 ± 95) , and ( 123 ± 96) cm^2 , respectively, and there was no statistically significant difference among them ( F = 1.55, P 〉 0.05). The ICC among 3 physicians was 0. 999. (2) The wound area of limbs of patients measured by transparency tracing method, NIH Image J method, and three dimensional human body scanning system BurnCalc was ( 84 ± 50), (76± 46), and ( 84 ± 49 ) cm^2 , respectively. There was no statistically significant difference in the wound area of limbs of patients measured by transparency tracing method and three dimensional human body scanning system BurnCalc ( P 〉 0.05). The wound ar

同期刊论文项目
同项目期刊论文
期刊信息
  • 《中华烧伤杂志》
  • 北大核心期刊(2011版)
  • 主管单位:中国科学技术协会
  • 主办单位:中华医学会
  • 主编:
  • 地址:重庆市沙坪坝区高滩岩正街29号
  • 邮编:400038
  • 邮箱:cmashz@mail.tmmu.com.cn
  • 电话:023-68754670 65460278
  • 国际标准刊号:ISSN:1009-2587
  • 国内统一刊号:ISSN:50-1120/R
  • 邮发代号:78-131
  • 获奖情况:
  • 中华医学会优秀期刊三等奖
  • 国内外数据库收录:
  • 美国化学文摘(网络版),波兰哥白尼索引,荷兰文摘与引文数据库,荷兰医学文摘,美国生物医学检索系统,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:10818