位置:成果数据库 > 期刊 > 期刊详情页
水体质量对大型梁式渡槽横向抗震性能影响研究
  • ISSN号:1000-0844
  • 期刊名称:《地震工程学报》
  • 时间:0
  • 分类:TV312[水利工程—水工结构工程]
  • 作者机构:[1]兰州交通大学甘肃省道路桥梁与地下工程重点实验室,甘肃兰州730070, [2]兰州交通大学土木工程学院,甘肃兰州730070
  • 相关基金:长江学者和创新团队发展计划资助(IRT1139);国家自然科学基金资助(10902045)
中文摘要:

通过对流固耦合动力作用简化方法的研究,用等效的弹簧-质量系统来模拟流体与渡槽结构的动力相互作用,并对某渡槽进行了多种地震波作用下的抗震性能分析,得到了大型梁式渡槽结构的自搌特性、地震响应.结果表明:槽内大质量水体对渡槽的横向地震响应有较大的影响,若不考虑槽内的水体将低估渡槽的地震反应;但因水体的晃荡作用减小了水体自身的地震反应,若将水体视为刚体附加到槽体上将严重地夸大水的地震惯性力作用.

英文摘要:

To analyze the transverse seismic performance of a large-scale beam aqueduct by consid- ering the water mass influence, the aqueduct of the South to North Water Diversion Project is studied. Through a study of the fluid-structure coupling dynamical action method, we use an e- quivalent of a spring-mass system (simplified using the Housner water model) for simulating the dynamic interaction of the fluid and the aqueduct structure. The ANSYS finite element software is adopted to estimate the performance of a large-scale aqueduct with a beam. With the time his- tory analysis method, we have investigated the transverse seismic response of the large-scale beam aqueduct using a few types of earthquake waves. Then, the natural vibration characteristics and the seismic response of the large-scale beam aqueduct are obtained considering the fluid-struc- ture coupling interaction. The calculation results show that the water shaking function has a con- siderable influence on the dynamic characteristics of the aqueduct. The transverse seismic re- sponse of the beam aqueduct is significantly influenced by the water mass in the aqueduct. The water shaking function can effectively decrease the seismic response of the water itself. The transverse seismic response of the aqueduct is underestimated if the water in the aqueduct is ig- nored; however, if all the water in the aqueduct is regarded as a rigid body and appended to the aqueduct, the seismic inertia action of the water is seriously exaggerated and is unreasonable. Consequently, in the dynamic analysis of the large-scale aqueduct, we must consider the fluid-structure coupling interaction. We compare a case in which the fluid-structure coupling interac- tion is considered and that in which the fluid-structure coupling interaction is not considered; the former's maximum top displacement and bottom moment and the shear of piers are far less than those of the latter. Therefore, we conclude that the water mass influence on the seismic response of the aqueduct is limited. W

同期刊论文项目
同项目期刊论文
期刊信息
  • 《地震工程学报》
  • 中国科技核心期刊
  • 主管单位:中国地震局
  • 主办单位:兰州地震研究所 清华大学 中国地震学会 中国土木工程学会
  • 主编:王兰民
  • 地址:甘肃省兰州市东岗西路450号
  • 邮编:730000
  • 邮箱:dzgcxb@gssb.gov.cn dzgcxb@yahoo.cn 2506121280@qq.com
  • 电话:0931-8275892
  • 国际标准刊号:ISSN:1000-0844
  • 国内统一刊号:ISSN:62-1208/P
  • 邮发代号:54-28
  • 获奖情况:
  • 中国地球物理学类核心期刊,中国地震局优秀科技期刊,中国科技论文统计源期刊
  • 国内外数据库收录:
  • 日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:975