人体头低脚高仰卧时下肢被动运动对背部肌肉疲劳的影响
  • ISSN号:1004-7220
  • 期刊名称:《医用生物力学》
  • 时间:0
  • 分类:R318.01[医药卫生—生物医学工程;医药卫生—基础医学]
  • 作者机构:[1]北京航空航天大学生物与医学工程学院、生物力学与力生物学教育部重点实验室、科技部“空天生物技术与医学工程”国际联合研究中心,北京100191
  • 相关基金:国家自然科学基金资助项目(10925208,11120101001,l1202017),教育部博士点新教师基金项目(20121102120039),北京市自然科学基金项目(7133245),北星摆颤一体脊柱梳理健身仪生物力学分析项目.
中文摘要:

目的研究人体头低位状态下肢被动运动对背部主要肌肉肌电(electromyogram,EMG)活动性的影响。方法选取30名健康受试者,分析竖脊肌和斜方肌在不同头低位角度(0°、10°、20°、27°)下静止状态、120次/min和140次/min足部摆动模式和680次/min足部颤动模式下EMG变化趋势。结果在头低位静止状态时,4种头低位角度下中位频率(mediafrequency,MF)随角度增加均呈下降趋势;摆动模式下,4种头低位角度的MF值均小于静止状态,且当摆动速度为120次/min时,MF值随角度增加而减小;速度为140次/min时,MF值无规律性变化。颤动模式下,MF值随头低位角度增大而增大,且均大于静止状态。结论静止状态下,肌肉疲劳程度随头低位角度增加而增加;颤动模式下应选择较小的头低位角度可更好达到锻炼治疗效果,摆动模式下可选择较大的头低位角度有助于较好达到锻炼治疗效果。此外,为避免肌肉过度疲劳造成劳损,摆动速度应不大于120次/min。

英文摘要:

Objective To study the effect of passive motion from lower extremity on electromyography (EMG) activity of major muscles when the back under head-down tilting state. Methods Thirty healthy subjects were se- lected. The EMGs of erector spinal and trapezius muscles were recorded and analyzed when human body was under head-down tilting at angel of 0°, 10°, 20° and 27° in static mode, respectively, in sway mode (along the axis of Z with frequencies of 120 and 140/min, respectively) and in vibration mode (along the axis of Y with fre- quency of 680/min) with the help of multifunctional test bed. Results In the static mode, the median frequency (MF) decreased with the increase of head-down titling angle; in the sway mode, the MF at each of 4 head-down tilting angles was smaller than that in the static mode. When the frequency was 120/min, the MF decreased with head-down tilting angle increasing, but when the frequency reached 140/rain, the variation of MF became irregu- lar. In the vibration mode, the MF increased with the increase of head-down tilting angle and was larger than thatin the static mode. Conclusions In the static mode, the muscle fatigue increased with the head-down tilting an- gle increasing; in the vibration mode, smaller head-down tilting angle should be selected to achieve better treat- ment effect; but in the sway mode, larger head-down tilting angle would be better, and the sway frequency should be set lower than 120/min to avoid potential damage due to excessive muscle fatigue.

同期刊论文项目
期刊论文 120 会议论文 6 著作 1
同项目期刊论文
期刊信息
  • 《医用生物力学》
  • 北大核心期刊(2011版)
  • 主管单位:教育部
  • 主办单位:上海交通大学
  • 主编:戴尅戎
  • 地址:上海市制造局路639号
  • 邮编:200011
  • 邮箱:shengwulixue@163.com
  • 电话:021-53315397
  • 国际标准刊号:ISSN:1004-7220
  • 国内统一刊号:ISSN:31-1624/R
  • 邮发代号:4-633
  • 获奖情况:
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),英国农业与生物科学研究中心文摘,波兰哥白尼索引,荷兰文摘与引文数据库,美国剑桥科学文摘,中国中国科技核心期刊,中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:4565