从压力波法测量平板样本中空间电荷分布的理论分析出发,提出了对于同轴结构的固体电介质中空间电荷分布的压力波法测量的物理模型,并得出了测量电流的解析的数学表达式.依据泊松方程,考虑样品内的电场强度、介电常数和空间电荷密度随外界声波扰动而发生变化,将圆柱试样受到的压力波的影响分解成样品形变和质点位移两部分,进而得到了以同轴结构中空间电荷分布的压力波法测量的电压与电流表达式.测量电流的数学表达式表明,对于同轴结构,压力波法的测量电流信号不像平板结构中那样基本正比于空间电荷分布,而是应该做进一步的修正处理.
With the rapid development of the science and technology, the application of the high voltage power cable has become more and more extensive. Now, it is generally accepted that space charge has an important effect on the electrical properties of insulating material in a high voltage cable. The measurement of space charge is the research base for the behaviors and properties of space charge in the polymer dielectric. Actually, the pressure wave propagation (PWP) method and pulsed electroacoustic (PEA) method are two sophisticated methods of measuring the space charge. However, these two methods are based on a planar sample. For measuring the space charge in a real cable, it is necessary to need the correct and precise mathematical expressions for the PWP method and PEA method. According to the theoretical analysis of the space charge distributions in the plate samples, measured by the pressure wave propagation method, we propose a physical model and its mathematical method of treating space charge distribution data measured in a coaxial geometry. In terms of Poisson equation, the influences of pressure waves on coaxial samples can be divided into two parts, namely, sample deformation and particle displacement. These two parts take into consideration the variations of the sample electric field, dielectric constant and density of space charge disturbed by pressure waves. Therefore, the voltage and current equations about the space charge distribution in the coaxial structure are found. The mathematical expression for the current measured indicates that compared with the current measured in the planar structure, which is proportional to the space charge distribution, the current signal measured in the coaxial structure should be further corrected. This paper also shows the experimental results which are the induced current signals picked from the planar sample and coaxial sample respectively. The results indicate that the current measured in the planar sample is proportional to the space charge distribution.