中红外光谱法无创伤检测血糖的新进展
  • ISSN号:1000-0593
  • 期刊名称:《光谱学与光谱分析》
  • 时间:0
  • 分类:O657.3[理学—分析化学;理学—化学]
  • 作者机构:[1]北京大学化学与分子工程学院,北京分子科学国家实验室,北京100871, [2]中国地质大学材料科学与工程学院,北京100083, [3]University of Saskatchewan, Canada S7N5C9, [4]杭州师范大学有机硅化学与材料重点实验室,浙江杭州310015, [5]瑞利分析仪器公司,北京100016
  • 相关基金:国家自然科学基金项目(30371604 50673005 50973003); 国家重点基础研究发展规划项目(2002CCA01900); 教育部博士点基金项目资助
中文摘要:

应用中红外光谱法对手指、血液以及干燥后的血液进行了测定,并同时与血糖仪测定的血糖作对比研究。研究结果表明,对红外光谱图进行分析时,选择1455cm^-1附近的谱峰作为基准峰,可使1120cm^-1附近的谱带得到准确度较高的相对强度。干燥后的血液与手指的光谱图大致相似并且与实测的血糖值的投点图具有相近的斜率,说明中红外光谱法检测人体血糖具有较高的可靠性。对同一手指进行不同时间的测定,以1120cm^-1谱带强度来表征血糖的浓度,其随时间的增加而增加,是因为人体内的葡萄糖不仅存在于血液中,而且也存在于皮肤的分泌物中,而分泌物会随时间的增加而增加。根据测定的1120cm^-1谱带的相对强度与实测血糖值所得的线性关系图表明,洗手后10min的准确度要高于4min。

英文摘要:

The blood glucose concentrations of volunteers from diabetes patients and healthy adults (all patients and volunteers who joined this experiment gave their consents) were measured by using a modified WQF-200 FTIR spectrometer with a newly designed ATR accessory from the Beijing Rayleigh Analytical Instrument Corp.The determination basis for this technique from the physiological point of view is also discussed based on the experimental results,which indicated that the glucose measured by the FT-Mid-IR-ATR instrument is from the secretions on the skin and glucose components within the body.The secreted glucose components will increase with the time increasing.The authors’ previous study demonstrated 1 120 cm^-1 band as an index to characterize the blood glucose.During the experiments,the authors used the band of 1 455 cm^-1 as internal standard because of its stability,and because the relative intensity of I1 120/I1 455 band possesses the higher sensitivity.Meanwhile,from the spectra,the relative intensity of I1 120/I1 455 band of the glucose in both sources exhibits a linear relationship with blood glucose concentration within the body.The dried blood has the similar spectra as fingers’.The fingers’ spectra will exhibit higher sensitivity if the time of measurement is longer after washing hand,and the results showed that when measured 10 minutes after washing hand,the sensitivity will be higher than that when measured 4 minutes after washing hand.All the results can be used in promoting a convenient,rapid and noninvasive way to monitor the continuous variation of blood glucose concentration of diabetes patients in real time.

同期刊论文项目
期刊论文 63 会议论文 13
同项目期刊论文
期刊信息
  • 《光谱学与光谱分析》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国光学学会
  • 主编:高松
  • 地址:北京海淀区魏公村学院南路76号
  • 邮编:100081
  • 邮箱:chngpxygpfx@vip.sina.com
  • 电话:010-62181070
  • 国际标准刊号:ISSN:1000-0593
  • 国内统一刊号:ISSN:11-2200/O4
  • 邮发代号:82-68
  • 获奖情况:
  • 1992年北京出版局编辑质量奖,1996年中国科协优秀科技期刊奖,1997-2000获中国科协择优支持基础性高科技学术期刊奖
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国生物医学检索系统,美国科学引文索引(扩展库),英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:40642