电喷雾萃取电离-三重四极杆质谱快速检测PVC医疗器械中残留环己酮的方法研究
  • ISSN号:0567-7351
  • 期刊名称:《化学学报》
  • 时间:0
  • 分类:TQ234.21[化学工程—有机化工]
  • 作者机构:[1]中国科学院合肥物质科学研究院医学物理与技术中心,合肥230031, [2]中国科学院合肥物质科学研究院安徽光学精密机械研究所,合肥230031
  • 相关基金:国家自然科学基金(Nos.21477132,81401756); 国家科技支撑计划(No.2015BAI01B04); 安徽省科技攻关项目(No.1301042095); 合肥物质科学技术中心创新项目培育基金(No.2014FXCX007)资助
中文摘要:

环己酮是一种广泛使用在PVC医疗器械生产中的粘接剂,残留的环己酮会通过输液或介入治疗等过程进入人体而产生潜在危害,快速检测残留环己酮对PVC医疗器械的质量控制具有重要意义.结合三重四极杆质谱和电喷雾萃取电离技术,建成能够对痕量环己酮气体快速检测的电喷雾萃取电离-三重四极杆质谱仪(EESI-MS/MS).通过对EESI电离源的喷雾电压、载气流速等条件进行优化,得到最优喷雾电压为3000 V,最佳载气流速为11.67 L/min,装置响应时间小于2.5 s,信号强度的相对标准偏差为4.83%,仪器的检出限为237.1×10^-9(V/V).利用EESI-MS/MS实现了对PVC输液管中残留环己酮的快速检测,配合串级质谱的子离子扫描功能实现了环己酮的准确定性,同时计算得到PVC输液管中残留环己酮的浓度为362.6×10^-9(V/V).建立的EESI-MS/MS在PVC医疗器械质量控制方面具有重要的应用价值.

英文摘要:

Cyclohexanone is widely used as adhesive in the production of PVC medical devices. Residual cyclohexanone in PVC medical devices may enter into human body through transfusion or intervention treatment, which can cause potential harm to human body. Therefore, rapid detection of the residual cyclohexanone is important to quality control of PVC medical devices. Based on the conventional electrospray ionization mass spectrometer/mass spectrometer(ESI-MS/MS), an extractive electrospray ionization mass spectrometer/mass spectrometer(EESI-MS/MS) for detection of trace cyclohexanone gas was built. The EESI technique can directly analyze the gas and liquid samples without pre-treatment, and the tandem mass spectrometry can unambiguously identify ions with the scan mode of product ions. To improve the performance of the instrument, effective parameters for rapid detection of cyclohexanone were optimized first of all. Laboratory air as sample, spray voltage of EESI was optimized to be 3000 V; Standard acetone gas as sample, carrier gas flow was optimized to be 11.67 L/min. And then the performance of the EESI-MS/MS was evaluated. The standard acetone gas was used as sample to test response time and repeatability(n=6) of the apparatus. The result showed that the response time of this EESI-MS/MS was less than 2.5 s, providing a real-time detection. And on the basis of 6 injections of the same sample, relative standard deviation(RSD) of signal intensities for acetone was 4.83%. A calibration curve was lined and the(limit of detection) LOD of the instrument was calculated to be 237.1×10^-9(V/V) with(signal/noise) S/N=3. Finally, EESI-MS/MS was used for fast detection of residual cyclohexanone gas in PVC infusion set. Comparing the mass spectra of standard cyclohexanone gas and air in the PVC infusion set, we found they all contained ions at m/z 99 and m/z 81. MS/MS technology was then used to make further investigation of the origin of the ions at m/z 99 from the air in the PVC infusion set and the

同期刊论文项目
同项目期刊论文
期刊信息
  • 《化学学报》
  • 北大核心期刊(2014版)
  • 主管单位:中国科学院
  • 主办单位:中国化学会 中国科学院上海有机化学研究所
  • 主编:周其林
  • 地址:上海市零陵路345号
  • 邮编:200032
  • 邮箱:hxxb@sioc.ac.cn
  • 电话:021-54925085
  • 国际标准刊号:ISSN:0567-7351
  • 国内统一刊号:ISSN:31-1320/O6
  • 邮发代号:4-209
  • 获奖情况:
  • 首届国家期刊奖,第二届国家期刊奖提名奖,中国期刊方阵“双高期刊”
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国科学引文索引(扩展库),日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:28694