分析评述了以“气-渣-金”化学平衡渣法研究渣系磷容量的方法和步骤,并以此测定了CaO—SiO2-Al2O3-MgO—Fe2O渣系的磷容量。正确选择气体混合物,反应容器和金属溶剂,正确配料-包括配制金属溶剂需要的有关材料和适合渣料需要的预备渣,以及正确选择平衡所需要的时间,是实验成功的关键。
The method to study phosphorus capacity in slags by means of gas-slag-metal equilibrium was analyzed, and phosphorus capacity of CaO-SiO2-Al2O3-MgO-Fe2O slag was measured by this method. The correct selecting gas mixture and and time for previous preparation of suitable related alloys and pre-fused slags is necessary to test. Reaction vessel equilibrium are the key factors for sucessful measurement.