  • 作者机构:[1]Key Laboratory of Neutronics and Radiation Safety, Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei 230031, China, [2]Engineering Technology Research Center of Accurate Radiotherapy of Anhui Province, Hefei 230031, China, [3]Collaborative Innovation Center of Radiation Medicine of Jiangsu Higher Education Institutions, SuZhou 215006, China
  • 相关基金:Supported by the National Natural Science Foundation of China (No 81101132) and the Natural Science Foundation of Anhui Province (No 11040606Q55)
  • 相关项目:逆向放射治疗计划系统中关键技术研究
中文摘要:

The reliability of radiotherapy was evaluated and effective approaches were obtained in order to improve radiotherapy quality by using the Probabilistic Safety Assessment(PSA) method. This study investigated the feasibility of the PSA method being applied to radiotherapy through Image-guided Radiotherapy(IGRT) and chest tumor irradiation. A fault tree has been constructed after analyzing causal relationship of the events.After calculating Risk A, a total inaccuracy radiotherapy probability and the importance of all base events were obtained. The probability of inaccurate radiotherapy was 2.87%. Under the condition that the target delineation was perfectly right, the accuracy of radiotherapy significantly improved. With the calculation without Conebeam Computed Tomography(CBCT) being corrected before irradiation, the accuracy significantly decreased.The most important events were connected with the human factor. Improving human technical level could enhance radiotherapy quality control efficiently.

英文摘要:

The reliability of radiotherapy was evaluated and effective approaches were obtained in order to improve radiotherapy quality by using the Probabilistic Safety Assessment(PSA) method. This study investigated the feasibility of the PSA method being applied to radiotherapy through Image-guided Radiotherapy(IGRT) and chest tumor irradiation. A fault tree has been constructed after analyzing causal relationship of the events.After calculating Risk A, a total inaccuracy radiotherapy probability and the importance of all base events were obtained. The probability of inaccurate radiotherapy was 2.87%. Under the condition that the target delineation was perfectly right, the accuracy of radiotherapy significantly improved. With the calculation without Conebeam Computed Tomography(CBCT) being corrected before irradiation, the accuracy significantly decreased.The most important events were connected with the human factor. Improving human technical level could enhance radiotherapy quality control efficiently.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《核技术:英文版》
  • 主管单位:中国科学院
  • 主办单位:中国科学院上海应用物理研究所 中国核学会
  • 主编:马余刚
  • 地址:上海市800-204信箱
  • 邮编:201800
  • 邮箱:nst@sinap.ac.cn
  • 电话:021-39194048
  • 国际标准刊号:ISSN:1001-8042
  • 国内统一刊号:ISSN:31-1559/TL
  • 邮发代号:4-647
  • 获奖情况:
  • 1996年获中科院优秀期刊三等奖
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),美国科学引文索引(扩展库),英国科学文摘数据库,英国英国皇家化学学会文摘
  • 被引量:57