位置:成果数据库 > 期刊 > 期刊详情页
脊柱颈胸结合部C5-T2三维有限元建模与验证
  • ISSN号:1004-7220
  • 期刊名称:《医用生物力学》
  • 时间:0
  • 分类:R318.01[医药卫生—生物医学工程;医药卫生—基础医学]
  • 作者机构:[1] 上海理工大学医疗器械与食品学院,上海200093, [2] 上海市第一人民医院骨科,上海200080, [3] 复旦大学力学与工程科学系,上海200433, [4] 上海理工大学能源与动力工程学院,上海200093
  • 相关基金:国家自然科学基金资助项目(51106099); 上海市教委科研创新项目(12YZ109); 上海市自然科学基金资助项目(15ZR1429600).
中文摘要:

目的基于CT图像数据建立人体脊柱颈胸结合部C5-T2的三维有限元模型,并验证模型的正确性和有效性。方法采用Mimics、Geomagic和Hypermesh软件对人体脊柱颈胸结合部C5-T2椎体进行三维重建、模型修复和有限元前处理,对模型顶面施加±0.5、1、1.5、2 N·m扭矩,用于模拟人体前屈和后伸活动时所产生的载荷作用,使用ANSYS软件计算脊柱颈胸结合部C5-T2节段在前屈和后伸承受扭矩载荷作用时的关节活动度(range of motion,ROM),将计算结果与前人研究结果进行对比分析。结果人体脊柱颈胸结合部C5-T2三维模型中C5-6、C6-7、C7-T1和T1-2各节段椎体在1 N·m载荷作用下,前屈时ROM分别为4.30°、3.21°、1.66°和1.41°,后伸时ROM分别为3.47°、2.86°、0.96°和0.92°。前屈时最大应力出现在椎体前缘,后伸时椎体后缘出现较大应力。ROM和应力分布的趋势与前人研究结果相一致。结论建立的脊柱颈胸结合部三维模型精确逼真,符合脊柱颈胸结合部的生物力学特性,模拟结果可为临床病理研究和颈胸部手术术式的评价提供理论依据。

英文摘要:

Objective To establish a 3D finite element model of cervicothoracic spinal segments C5-T2 based on CT images and test its validity and effectiveness. Methods By using the Mimics,Geomagic and Hypermesh software,the 3D model of cervicothoracic spinal segments C5-T2 was reconstructed,repaired and pre-processed. Moment of ± 0. 5,1,1. 5,2 N·m were applied on top of the model to simulate loads produced during the flexion and extension movement of human body. The range of motion( ROM) of the segments C5-T2 during flexion and extension was calculated by ANSYS,and the reliability of the model was verified by comparing the experimental results in the previous literature with the finite element analysis results obtained in this study. Results Under the moment of 1 N·m,the ROMs of C5-6,C6-7,C7-T1 and T1-2 during flexion were 4. 30°,3. 21°,1. 66°and 1. 41°,and those during extension were 3. 47°,2. 86°,0. 96° and 0. 92°,respectively. The maximum stress during flexion appeared on the front of the vertebral body,while that during extension appeared on the back of the vertebral body. The trends of ROM and stress distributions were consistent with results reported in the previous literature. Conclusions The 3D model established in this study is accurate and realistic,and conforms to biomechanical properties of the cervicothoracic spine. The simulation results can be further used to explore clinical pathology of the spine and provide theoretical references for evaluation on cervicothoracic spine surgery.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《医用生物力学》
  • 北大核心期刊(2011版)
  • 主管单位:教育部
  • 主办单位:上海交通大学
  • 主编:戴尅戎
  • 地址:上海市制造局路639号
  • 邮编:200011
  • 邮箱:shengwulixue@163.com
  • 电话:021-53315397
  • 国际标准刊号:ISSN:1004-7220
  • 国内统一刊号:ISSN:31-1624/R
  • 邮发代号:4-633
  • 获奖情况:
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),英国农业与生物科学研究中心文摘,波兰哥白尼索引,荷兰文摘与引文数据库,美国剑桥科学文摘,中国中国科技核心期刊,中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:4565