将萃取与回流相结合,建立了一种处理航空润滑油中磨损金属的新方法,并用MPT全谱仪对磨损金属含量进行了同时检测.该方法基本上实现了样品处理的全自动化,克服了常用方法的部分缺点,对Zn,Cd,Cu,Fe和Ph的检出限(3σ)分别为0.084,0.043,0、022,0.052和0.064μg/g;相对标准偏差均小于5%(n=5);回收率为94.5%~107.4%、对3个润滑油样品的检测结果令人满意.
A novel, simple and economic sample pretreatment system based on reflux extraction was developed for the determination of wear metals in the used aviation lubricating oil by using a simultaneous microwave plasma torch atomic emission spectrometer(MPT-AES). The operating parameters for both sample pretreatment and analysis were studied and optimized. The detection limits are 0. 084, 0. 043, 0. 022, 0. 052, 0. 064 μg/g for Zn, Cd, Cu, Fe and Pb, respectively. The relative standard deviations are less than 5% (n = 5) , and the recovery ratios of these elements are in the range of 94. 5%-107.4%. The new system was suecessfully applied to the analysis of the lubricating oil samples.