位置:成果数据库 > 期刊 > 期刊详情页
吸气式火灾探测系统采样管网优化设计
  • ISSN号:1009-6094
  • 期刊名称:《安全与环境学报》
  • 时间:0
  • 分类:X932[环境科学与工程—安全科学]
  • 作者机构:[1]中国科学技术大学火灾科学国家重点实验室,合肥230027
  • 相关基金:国家重点基础研究发展(973)计划项目(2012CB719702); 科技部火炬计划项目(2010GH591095)
中文摘要:

对吸气式火灾探测报警系统中采样管网进行优化设计是提高其探测性能的重要手段。基于流体动力学原理,建立管网内气体运动数学模型,给出各状态参数之间的关系式。分析常见管网布置方式的优缺点,提出吸气式采样管网的优化设计方案:视每个采样孔为1个点型感烟探测器,采样孔间距基本一致,调整孔径使各采样孔进气量相同,孔数较多时,可增设末端孔,以缩短气体样本传输时间。从理论上分析管网参数对探测性能的影响,并利用Fluent 6.3进行相应的数值模拟。结果表明,样本传输时间与管长、管径、开孔数成正比,与总流量和末端孔孔径成反比。

英文摘要:

This paper aims to present our optimized design version of pipe network for aspirating fire detective alarming system in hoping to enhance the fire alarming behavior.In our paper,we have established a physical and mathematical model of gas sucking-up in sampling pipe network based on the fluid dynamic principle and investigated the relation of the state parameters of gas-sampling,such as the gas pressure,velocity,the local loss and frictional loss from the theoretical point of view.In so doing,we have fully described the two most favorable methods of pipe design at present,and analyzed their advantages and disadvantages of the said system.Furthermore,we have worked out a new project by adjusting the diameters of sampling holes to ensure their air-input rate equally and making it as a spot-type detector by increasing the sensitivity of each sampling port of aspirating smoke detector.While keeping the distance of all the sampling ports equal,we have managed to change their positions in accordance with the specific conditions of the area.The hole in the end cap has been particularly laid out so as to reduce the gas-transferring time.In our optimized design version of the pipe network,we have taken particular measures to keep the balance of the gas-flowing rate of sampling holes so as to maximize the gas sampling transferring time from the farthest sampling point to the detector within 120 seconds.If such demands cannot be satisfied,it would be necessary to adjust the diameter of the sampling port,or change the structure of network,such as the length of the sampling pipes or the number of the sampling holes.And,finally,the paper has also made a discussion of the effects of various parameters on the gas transferring time by taking the advantages of the original mathematical model.At the same time,we have also adopted some commercial CFD software(e.g.Fluent 6.3) to simulate the working conditions of the smoke detector,and recorded the transferring time of the gas sample in the different parts of pipe network.The th

同期刊论文项目
同项目期刊论文
期刊信息
  • 《安全与环境学报》
  • 北大核心期刊(2011版)
  • 主管单位:中国兵器工业集团公司
  • 主办单位:北京理工大学 中国环境科学学会 中国职业安全健康协会
  • 主编:冯长根
  • 地址:北京市海淀区中关村南大街5号
  • 邮编:100081
  • 邮箱:aqyhjxb@263.net;aqyhjxb@wuma.com.cn
  • 电话:010-68913997
  • 国际标准刊号:ISSN:1009-6094
  • 国内统一刊号:ISSN:11-4537/X
  • 邮发代号:2-770
  • 获奖情况:
  • 获首届《CAJ-CD》执行优秀期刊奖,中国科技论文统计源期刊
  • 国内外数据库收录:
  • 美国化学文摘(网络版),中国中国科技核心期刊,中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:17182