位置:成果数据库 > 期刊 > 期刊详情页
使用氟化钡作为固定相的薄层色谱-红外光谱联用研究
  • ISSN号:1000-0593
  • 期刊名称:Spectroscopy and Spectral Analysis
  • 时间:0
  • 页码:1767-1771
  • 分类:O657.3[理学—分析化学;理学—化学]
  • 作者机构:[1]辽宁中医药大学药学院,辽宁沈阳110032, [2]北京大学化学与分子工程学院,北京100871, [3]北京化工大学化学工程学院,北京100029, [4]河北师范大学化学与材料科学学院,河北石家庄050016, [5]沈阳度太生物制药研究中心,辽宁沈阳110031, [6]北京大学第三医院危重医学科,北京110083
  • 相关基金:国家自然科学基金项目(50973003 20975029); 国家科技部(863)重大项目(MOST2010AA03A406); 北京大学先进技术研究院培育项目资助
  • 相关项目:尼龙6及稀土尼龙复合物的加工-结构-性能关系研究
中文摘要:

原位薄层色谱-红外光谱联用在分析复杂混合物上有巨大潜力,但因固定相自身的红外吸收严重干扰样品检测,该方法进展缓慢。本文应用对中红外光透明的氟化钡微小颗粒作为固定相制备薄层层析板,并对该板的层析效果及原位显微反射红外光谱检测的可行性进行了初步的探讨。通过优化反应条件,制备出粒径为500 nm左右的氟化钡颗粒;发展出一种制备薄层层析板的新技术——沉降-挥发法;通过实验证明,新型薄层板具备分离混合物的能力;原位红外光谱检测结果表明氟化钡作为固定相不干扰样品的检测。应用氟化钡作为新型薄层板固定相,为从技术上实现原位薄层色谱-红外光谱联用打开了大门。

英文摘要:

In situ TLC/FTIR technique has tremendous potential in the analysis of complex mixtures.However,the progress in this technique was quite slow.The reason is that conventional stationary phase such as silica gel etc.has strong absorption in FTIR spectrum and thus brings about severe interference in the detection of samples.To solve the problem,the authors propose to use barium fluoride fine particles as stationary phase of TLC plate.The reasons are as follows: Barium fluoride wafer has been extensively used as infrared window in FTIR experiments and it has no absorbance in an IR region between 4 000 and 800 cm-1.As a matter of fact,the atomic mass of barium and fluoride is quite large,thus the normal vibration of BaF2 lattice is limited in far-IR region and low frequency part of mid-IR region.Therefore,the interference caused by IR absorption of stationary phase can be resolved if BaF2 is used as stationary phase of TLC plate.Moreover,BaF2 is quite stable and insolvable in water and most organic solvents and it will not be dissolved by mobile phase or react with samples in TLC separation.Additionally,decreasing the particle size of BaF2 is very important in TLC/FTIR analysis technique.The reason is two-fold: First,decreasing the particle size of stationary phase is helpful to improving the efficiency of separation by TLC plate;second,decreasing the size of BaF2 particle can improve the quality of FTIR spectra by alleviating the problem of light scattering.By optimizing the synthetic conditions,fine particles of barium fluoride were obtained.SEM results indicate that the size of the BaF2 particles is around 500 nm.FTIR spectrum of the BaF2 particles shows that no absorption of impurity was observed.Moreover,the elevation of baseline caused by light scattering is insignificant.The authors have developed a new technique named "settlement volatilization method" to prepare TLC plate without polymeric adhesive that may bring about significant interference in FTIR analysis.Preliminary TLC experiments proved that t

同期刊论文项目
同项目期刊论文
期刊信息
  • 《光谱学与光谱分析》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国光学学会
  • 主编:高松
  • 地址:北京海淀区魏公村学院南路76号
  • 邮编:100081
  • 邮箱:chngpxygpfx@vip.sina.com
  • 电话:010-62181070
  • 国际标准刊号:ISSN:1000-0593
  • 国内统一刊号:ISSN:11-2200/O4
  • 邮发代号:82-68
  • 获奖情况:
  • 1992年北京出版局编辑质量奖,1996年中国科协优秀科技期刊奖,1997-2000获中国科协择优支持基础性高科技学术期刊奖
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国生物医学检索系统,美国科学引文索引(扩展库),英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:40642