位置:成果数据库 > 期刊 > 期刊详情页
一种液晶透镜盒间隙的测试方法
  • ISSN号:1000-3290
  • 期刊名称:《物理学报》
  • 时间:0
  • 分类:O212.1[理学—概率论与数理统计;理学—数学]
  • 作者机构:[1]上海交通大学,TFT-LCD关键材料及技术国家工程实验室,上海200240, [2]昆山龙腾光电有限公司,昆山215301, [3]国立交通大学,台湾
  • 相关基金:江苏省省科技支撑计划(批准号:BE2012862)、国家自然科学基金(批准号:60906039)和上海自然科学基金(批准号:09ZR1414800)资助的课题.
中文摘要:

针对当前液晶透镜盒问隙测试存在的难题,文中提出采用线偏振干涉法测试方法,采用光强均匀分布的单色光入射,检偏器的偏光轴方向与起偏器的偏光轴垂直或者平行,液晶透镜的液晶取向层的摩擦方向与起偏器偏振轴夹角为45°,此时干涉条纹亮暗差别最明显.利用液晶透镜中心保持预倾角不变的透过率以及其他位置透过率最大值来计算液晶透镜的盒间隙,该方法简单、可靠,因采用光学手段测试,其精确度相对较高.

英文摘要:

There was a problem in current cell gap measurement of liquid crystal (LC) lens. A method was proposed by adopting interference of linearly polarized light in this paper. It was claimed that the incident light was monochromatic light with a uniform distribution of light intensity. The polarization axis of the analyzer was perpendicular or parallel to the polarization axis of polarizer. The difference between light and dark interference fringes was the biggest when the angle was equal to 45~ between the rubbing direction of alignment layer in the LC lens and the polarization axis of polarizer. The cell gap of LC lens can be calculated by the transmittance of LC lens center and the max transmittance of its other locations. The tilt angle was equal to the pre-tilt angle of LC at the LC lens center. This method was simple and reliable. Its accuracy is relatively high due to the use of optical interference principle.

同期刊论文项目
期刊论文 16 会议论文 10 专利 6
同项目期刊论文
期刊信息
  • 《物理学报》
  • 北大核心期刊(2011版)
  • 主管单位:中国科学院
  • 主办单位:中国物理学会 中国科学院物理研究所
  • 主编:欧阳钟灿
  • 地址:北京603信箱(中国科学院物理研究所)
  • 邮编:100190
  • 邮箱:apsoffice@iphy.ac.cn
  • 电话:010-82649026
  • 国际标准刊号:ISSN:1000-3290
  • 国内统一刊号:ISSN:11-1958/O4
  • 邮发代号:2-425
  • 获奖情况:
  • 1999年首届国家期刊奖,2000年中科院优秀期刊特等奖,2001年科技期刊最高方阵队双高期刊居中国期刊第12位
  • 国内外数据库收录:
  • 美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国科学引文索引(扩展库),英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:49876