根据北京市冬季气温调研,确定室内冻融循环试验周期,分别对7组环氧沥青混凝土试件进行不同次数的冻融循环,通过室内三点弯曲试验得到不同冻融循环次数下环氧沥青混凝土的弯曲劲度模量和断裂能,采用数值模拟方法计算不同冻融循环次数下环氧沥青混凝土的平面应变断裂韧度.研究结果表明:环氧沥青混凝土弯曲劲度模量随冻融循环次数的增加而减小,冻融循环次数为30次时,环氧沥青混凝土弯曲劲度模量的冻融损伤量为60%;环氧沥青混凝土断裂能和平面应变断裂韧度随冻融循环次数的增加呈先减小后增大的趋势,冻融循环为15次时,环氧沥青混凝土断裂能和平面应变断裂韧度达到最小值.
According to the winter temperature of Peking,the freeze-thaw(FT) condition in laboratory was determined.Seven groups of epoxy asphalt concrete(EAC) specimen were exposed to different FT cycles.The flexural modulus and fracture energy(G_F) of EAC exposed to different FT cycles were obtained through the 3-point bending test.Meanwhile,the plane strain fracture toughness(K_(IC)) of EAC was obtained through numerical simulation.The results show that the flexural modulus of the FT conditioned EAC samples decreases with the increase of FT cycles.The FT damage of flexural modulus is 60%after 30 FT cycles.Nevertheless,with the increase of FT cycles,the G_F and K_(IC) of EAC decrease first and then increase after 15 FT cycles.