位置:成果数据库 > 期刊 > 期刊详情页
Analog rise-time discriminator for CdZnTe detector
  • ISSN号:0258-0934
  • 期刊名称:《核电子学与探测技术》
  • 时间:0
  • 分类:TL[核科学技术]
  • 作者机构:[1]Chengdu University of Technology, Chengdu 610059, China, [2]National Ocean Technology Center, Tianjin 300112, China
  • 相关基金:This work was supported by the Natural Science Foundation of China (NSFC) (No. 41474159), National High-tech R&D Program of China (863 Program) (Nos. 2012AA061803 and 2014AA093403) and Open Foundation of Applied Nuclear Techniques in Geosciences Key Laboratory of Sichuan Province (No. gnzds2014006).
中文摘要:

Due to variable time for charge collection,energy resolution of nuclear detectors declines, especially compound semiconductor detectors like cadmium zinc telluride (CdZnTe) detector. To solve this problem, an analog rise-time discriminator based on charge comparison principle is designed. The reference charge signal after attenuation is compared with the deconvoluted and delayed current signal. It is found that the amplitude of delayed current signal is higher than that of the reference charge signal when rise time of the input signal is shorter than the discrimination time, thus generating gating signal and triggering DMCA (digital multi-channel analyzer) to receive the total integral charge signal. When rise time of the input signal is longer than discrimination time, DMCA remains inactivated and the corresponding total integral charge signal is abandoned. Test results show that combination of the designed rise-time discriminator and DMCA can reduce hole tailing of CdZnTe detector significantly.Energy resolution of the system is 0.98%@662 keV, and it is still excellent under high counting rates.

英文摘要:

Due to variable time for charge collection, energy resolution of nuclear detectors declines, especially compound semiconductor detectors like cadmium zinc telluride (CdZnTe) detector. To solve this problem, an analog rise-time discriminator based on charge comparison principle is designed. The reference charge signal after attenuation is compared with the deconvoluted and delayed current signal. It is found that the amplitude of delayed current signal is higher than that of the reference charge signal when rise time of the input signal is shorter than the discrimination time, thus generating gating signal and triggering DMCA (digital multi-channel analyzer) to receive the total integral charge signal. When rise time of the input signal is longer than discrimination time, DMCA remains inactivated and the corresponding total integral charge signal is abandoned. Test results show that combination of the designed rise-time discriminator and DMCA can reduce hole tailing of CdZnTe detector significantly. Energy resolution of the system is 0.98%@662?keV, and it is still excellent under high counting rates.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《核电子学与探测技术》
  • 北大核心期刊(2011版)
  • 主管单位:中国核工业集团公司
  • 主办单位:中核(北京)核仪器厂
  • 主编:李卫国
  • 地址:北京经济技术开发区宏达南路3号
  • 邮编:100176
  • 邮箱:lw261@sina.com
  • 电话:010-59573451
  • 国际标准刊号:ISSN:0258-0934
  • 国内统一刊号:ISSN:11-2016/TL
  • 邮发代号:
  • 获奖情况:
  • 中国中文核心期刊,中国科协三等奖,中国核工业部二等奖
  • 国内外数据库收录:
  • 美国化学文摘(网络版),荷兰文摘与引文数据库,日本日本科学技术振兴机构数据库,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:6170