Starting the cracking gas compressor and precooling the refrigeration system are keys to start-up of an ethylene plant and accounts for up to 50% of the total start-up time and plant flare emissions. Premature feeding of cracking furnaces can be avoided if the cracking gas compressor is started and the refrigeration system is precooled in advance using mixed gas as the start-up working medium(SWM). Start-up scenario with mixed gas as SWM could significantly reduce the emission loss and shorten the precooling time. Research shows that making appropriate start-up scheme is important not only to ensure operational safety and feasibility, but also to reduce energy consumption. In this paper, a method is proposed to select suitable start-up operational parameters of compression and refrigeration system with sufficient safe operating ranges and short precooling time. The complex interrelation among key parameters of start-up is analyzed. It is found that higher energy consumption, especially for super high-pressure steam(SS), can promote operational safety and shorten the precooling time during start-up.Based on steady-state and dynamic simulation, appropriate operating parameter ranges are determined with reasonable SS consumption. A real case study demonstrates that an appropriate start-up scheme will optimize the operation.

英文摘要:

Starting the cracking gas compressor and precooling the refrigeration system are keys to start-up of an ethylene plant and accounts for up to 50% of the total start-up time and plant flare emissions. Premature feeding of cracking furnaces can be avoided if the cracking gas compressor is started and the refrigeration system is precooled in advance using mixed gas as the start-up working medium (SWM). Start-up scenario with mixed gas as SWM could significantly reduce the emission loss and shorten the precooling time. Research shows that making appropriate start-up scheme is important not only to ensure operational safety and feasibility, but also to reduce energy consumption. In this paper, a method is proposed to select suitable start-up operational parameters of compression and refrigeration system with sufficient safe operating ranges and short precooling time. The complex interrelation among key parameters of start-up is analyzed. It is found that higher energy consumption, especially for super high-pressure steam(SS), can promote operational safety and shorten the precooling time during start-up. Based on steady-state and dynamic simulation, appropriate operating parameter ranges are determined with reasonable SS consumption. A real case study demonstrates that an appropriate start-up scheme will optimize the operation. (C) 2016 The Chemical Industry and Engineering Society of China, and Chemical Industry Press. All rights reserved.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《中国化学工程学报:英文版》
  • 中国科技核心期刊
  • 主管单位:中国科协
  • 主办单位:中国化学工业与化学工程学会
  • 主编:
  • 地址:北京东城区青年湖路13号
  • 邮编:100011
  • 邮箱:cjche@cip.com.cn
  • 电话:010-64519487/88
  • 国际标准刊号:ISSN:1004-9541
  • 国内统一刊号:ISSN:11-3270/TQ
  • 邮发代号:
  • 获奖情况:
  • 1998年化工系统优秀信息成果一等奖,中国期刊方阵“双效”期刊
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国剑桥科学文摘,美国科学引文索引(扩展库),英国高分子图书馆,日本日本科学技术振兴机构数据库,中国中国科技核心期刊
  • 被引量:385