对带有静止励磁调节器的双绕组异步发电机控制绕组的无功容量进行了理论计算,分别在额定负载、1∶3转速变比和额定转速、空载到额定负载变化时控制绕组容量的变化规律进行了分析,得出了电动机参数变化、负载及原动机转速对控制绕组无功容量的影响规律。
The calculations on control winding reactive power of dual stator-winding asynchronous generator with static excitation regulator were proposed in the paper.The laws on reactive power of control winding were presented respectively under rated-load with the given 1 to 3 speed ratio and no-load to rated-load with rated speed.The influences on the reactive power of control winding by machine parameters and load and speed were given.