位置:成果数据库 > 期刊 > 期刊详情页
电感耦合等离子体质谱测定居住区大气中痕量铍、镉、砷、铅
  • ISSN号:1000-0593
  • 期刊名称:《光谱学与光谱分析》
  • 时间:0
  • 分类:O657.3[理学—分析化学;理学—化学] X513[环境科学与工程—环境工程]
  • 作者机构:[1]中国疾病预防控制中心环境与健康相关产品安全所,北京100021
  • 相关基金:卫生部《2007年卫生标准(制)修订项目》(2007-环-07); “十一五”国家科技支撑计划项目(2006BAI19B01)资助
中文摘要:

建立电感耦合等离子体质谱法测定居住区大气中铍、镉、砷、铅等痕量元素的分析方法。通过超声浸提同时分离气溶胶样品中多种元素,对仪器工作参数进行优化,选取72Ge,115In和204Tl作为测定元素的校正内标,有效克服了基体效应、接口效应和仪器漂移对测定信号产生的影响。测定元素标准曲线的相关系数均优于0.999 5,铍、镉、砷、铅各元素的测定方法检出限分别为0.022,0.020,0.018和0.130μg.L-1,方法定量限分别为0.102,0.093,0.083和0.602 ng.m-3。通过测定标准参考物质GBW(E)080212考察方法的准确性,测定值均在标准值范围内。取采样滤膜分别加入低、中、高浓度标准溶液进行测定,样品加标回收率为91.6%~109.7%,相对标准偏差介于0.7%~4.8%。该方法精密度好、准确性好,简便、快速、灵敏,适用于居住区大气中痕量元素铍、镉、砷、铅含量的测定。

英文摘要:

In the present paper,the method for determining the trace elements Be,Cd,As and Pb in air of residential areas by inductively coupled plasma-mass spectrometry was established.Ultrasonic leaching procedures were applied to extract the trace elements from the filter membrane of the atmospheric particulates.The operating condition of the instrument was optimized.72Ge,115In and 204Tl were chosen as the internal elements and the effect of matrix,interface and fluctuation of instrument was overcome effectively.Satisfactory linearity of working curves of four elements was obtained,giving all the correlation coefficients over 0.999 5,and the detection limit of the method was between 0.006 and 0.045 ng·m-3.The mean values of National Standard Reference Material GBW(E)080212 were in agreement with the certified values.The sampling filters membranes,divided into four equal parts and with added standard solution with different concentions were analyzed,and the recovery rate of samples were in the range of 91.6%~109.7% with the related standard deviation between 0.7% and 4.8%.The obtained results showed that the method of determining the trace elements Be,Cd,As and Pb in air of residential areas by inductively coupled plasma-mass spectrometry proved to be simple,accurate,sophisticated and stable.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《光谱学与光谱分析》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国光学学会
  • 主编:高松
  • 地址:北京海淀区魏公村学院南路76号
  • 邮编:100081
  • 邮箱:chngpxygpfx@vip.sina.com
  • 电话:010-62181070
  • 国际标准刊号:ISSN:1000-0593
  • 国内统一刊号:ISSN:11-2200/O4
  • 邮发代号:82-68
  • 获奖情况:
  • 1992年北京出版局编辑质量奖,1996年中国科协优秀科技期刊奖,1997-2000获中国科协择优支持基础性高科技学术期刊奖
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国生物医学检索系统,美国科学引文索引(扩展库),英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:40642