包被材料对磁性纳米粒胶束MRI信号和弛豫效能的影响
  • ISSN号:1000-5404
  • 期刊名称:第三军医大学学报
  • 时间:2013.1.1
  • 页码:5-9
  • 分类:R445.2[医药卫生—影像医学与核医学;医药卫生—诊断学;医药卫生—临床医学] R811.1[医药卫生—放射医学;医药卫生—临床医学]
  • 作者机构:[1]第三军医大学新桥医院放射科,重庆400037
  • 相关基金:国家自然科学基金面上项目(81071197); 十二五国家科技支撑计划(2012BAI23B08-4)~~
  • 相关项目:Endoglin双重靶向分子探针介导的肿瘤微血管和微淋巴管MRI成像与热治疗研究
中文摘要:

目的分析不同包被材料对磁性纳米粒(Magnetic nanoparticles,MNs)胶束的MRI信号及弛豫效能的影响。方法对两亲嵌段共聚物聚乙二醇/聚己内酯(PEG-b-PCL)和聚乙烯亚胺/聚己内酯(PEI-b-PCL)包被的铁酸锰(MnFe2O4)纳米粒胶束(PEG-b-PCL-MnFe2O4、PEI-b-PCL-MnFe2O4)行磁共振成像检查,观察不同浓度MNs胶束溶液MRI信号变化规律,测量纳米粒胶束的T1和T2弛豫时间,计算两种包被材料MNs胶束的r1值和r2值,评价不同包被材料对MnFe2O4纳米粒胶束弛豫效能的影响。结果 PEG-b-PCL-MnFe2O4和PEI-b-PCL-MnFe2O4溶液的信号变化规律基本一致,在T2WI和T2*WI,随着浓度的增加,信号强度逐渐降低,PEG-b-PCL-MnFe2O4较PEI-b-PCL-MnFe2O4降低更明显。在T1WI,信号强度先增高后降低,信号达到峰值时,PEG-b-PCL-MnFe2O4和PEI-b-PCL-MnFe2O4的浓度分别为0.2 mmol/L和0.4 mmol/L,浓度相同时,PEG-b-PCL-MnFe2O4较PEI-b-PCL-MnFe2O4的信号低。PEG-b-PCL-MnFe2O4和PEI-b-PCL-MnFe2O4的r2值分别为186.4(mmol/L)-1.s-1和83.3(mmol/L)-1.s-1,r1值分别为0.95(mmol/L)-1.s-1和1.09(mmol/L)-1.s-1,PEG-b-PCL-MnFe2O4较PEI-b-PCL-MnFe2O4的r2值高。结论包被材料对MNs胶束的弛豫效能产生明显影响,相对于PEI-b-PCL,PEG-b-PCL包被的纳米粒胶束具有更强的r2弛豫效能和较弱的r1弛豫效能。

英文摘要:

Objective To analyze the effect of coating materials on the magnetic resonance imaging(MRI) signal intensity and relaxivity of magnetic nanoparticles(MNs) micelles.Methods PEG-b-PCL-MnFe2O4 and PEI-b-PCL-MnFe2O4 MNs micelles,which were MnFe2O4 MNs coated with PEG-b-PCL and PEI-b-PCL,respectively,were examined by MRI.The MRI signal intensity of MNs micelles solution with different concentrations was observed,T1 and T2 relaxation time were measured,r1 and r2 values were calculated,and the effect of coating materials on the relaxivity of MNs micelles was evaluated.Results The MRI intensity of PEG-b-PCL-MnFe2O4 and PEI-b-PCL-MnFe2O4 solutions changed almost identically.With the increase of concentration,the signal intensity decreased in T2WI and T*2WI,and the signal intensity of PEG-b-PCL-MnFe2O4 solution decreased significantly compared with that of PEI-b-PCL-MnFe2O4 solution.The signal intensity of the two MNs micelles solutions increased firstly,and then decreased in T1WI.At the peak signal intensity,the concentrations were 0.2 mmol/L for PEG-b-PCL-MnFe2O4 and 0.4 mmol/L for PEI-b-PCL-MnFe2O4,and the signal intensity of PEG-b-PCL-MnFe2O4 was lower than that of PEI-b-PCL-MnFe2O4 at the same concentration.The r2 value of PEG-b-PCL-MnFe2O4 and PEI-b-PCL-MnFe2O4 was 186.4(mmol/L)-1·s-1 and 83.3(mmol/L)-1·s-1,and the r1 value of PEG-b-PCL-MnFe2O4 and PEI-b-PCL-MnFe2O4 was 0.95(mmol/L)-1·s-1 and 1.09(mmol/L)-1·s-1,respectively.Conclusion Coating materials affect the MRI signal intensity and relaxivity of MNs micelles significantly.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《第三军医大学学报》
  • 北大核心期刊(2011版)
  • 主管单位:第三军医大学
  • 主办单位:第三军医大学
  • 主编:钱桂生
  • 地址:重庆市沙坪坝区高滩岩30号第三军医大学学报编辑部
  • 邮编:400038
  • 邮箱:aammt@mail.tmmu.com.cn
  • 电话:023- 68752187
  • 国际标准刊号:ISSN:1000-5404
  • 国内统一刊号:ISSN:50-1126/R
  • 邮发代号:78-91
  • 获奖情况:
  • 先后20余次获全国、全军、教育部和省、市优秀科技...,2003年、2005年两度被评为"国家期刊奖百种重点科...
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),英国农业与生物科学研究中心文摘,波兰哥白尼索引,美国剑桥科学文摘,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:47530