位置:成果数据库 > 期刊 > 期刊详情页
Magnetic Fe3O4-Reduced Graphene Oxide Nanocomposites-Based Electrochemical Biosensing
  • ISSN号:0253-9837
  • 期刊名称:《催化学报》
  • 时间:0
  • 分类:O657.1[理学—分析化学;理学—化学] TP212.3[自动化与计算机技术—控制科学与工程;自动化与计算机技术—检测技术与自动化装置]
  • 作者机构:The Education Ministry Key Laboratory of Resource Chemistry and Shanghai Key Laboratory of Rare Earth Functional Materials,Department of Chemistry, College of Life and Environmental Sciences, Shanghai Normal University
  • 相关基金:supported by the National Natural Science Foundation of China (21373138);Shanghai Sci. & Tech. Committee (12JC1407200);Program for Changjiang Scholars and Innovative Research Team in University (IRT1269)
中文摘要:

An electrochemical biosensing platform was developed based on glucose oxidase(GOx)/Fe3O4-reduced graphene oxide(Fe3O4-RGO) nanosheets loaded on the magnetic glassy carbon electrode(MGCE).With the advantages of the magnetism, conductivity and biocompatibility of the Fe3O4-RGO nanosheets, the nanocomposites could be facilely adhered to the electrode surface by magnetically controllable assembling and beneficial to achieve the direct redox reactions and electrocatalytic behaviors of GOx immobilized into the nanocomposites. The biosensor exhibited good electrocatalytic activity, high sensitivity and stability. The current response is linear over glucose concentration ranging from 0.05 to 1.5 m M with a low detection limit of0.15 μM. Meanwhile, validation of the applicability of the biosensor was carried out by determining glucose in serum samples. The proposed protocol is simple, inexpensive and convenient, which shows great potential in biosensing application.

英文摘要:

An electrochemical blosensing platform was developed based on glucose oxidase (GOx)/Fe3O4-reduced graphene Oxide (Fe3O4-RGO) nanosheets loaded on the magnetic glassy carbon electrode (MGCE). With the advantages of the magnetism, conductivity and biocompatibility of the Fe3O4-RGO nanosheets, the nanocomposites could be facilely adhered to the electrode surface by magnetically controllable assembling and beneficial to achieve the direct redox reactions and electrocatalytic behaviors of GOx immobilized into the nanocomposites. The biosensor exhibited good electrocatalytic activity, high sensitivity and stability. The current response is linear over glucose concentration ranging from 0.05 to 1.5 mM with a low detection limit of 0.15 mu M. Meanwhile, validation of the applicability of the biosensor was carried out by determining glucose in serum samples. The proposed protocol is simple, inexpensive and convenient, which shows great potential in biosensing application.

同期刊论文项目
期刊论文 4
同项目期刊论文
期刊信息
  • 《催化学报》
  • 北大核心期刊(2011版)
  • 主管单位:中国科学院
  • 主办单位:中国化学会 中国科学院大连化学物理研究所
  • 主编:李灿 张涛
  • 地址:大连市沙河口区中山路457号
  • 邮编:116023
  • 邮箱:chxb@dicp.ac.cn
  • 电话:0411-84379240
  • 国际标准刊号:ISSN:0253-9837
  • 国内统一刊号:ISSN:21-1195/O6
  • 邮发代号:8-93
  • 获奖情况:
  • 第三届国家期刊奖提名奖,中国科协精品科技期刊示范项目
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国剑桥科学文摘,美国科学引文索引(扩展库),日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:19199