为满足非隔离光伏并网发电系统对共模漏电流的限制,提出一种六开关逆变器拓朴(H6拓扑)。所提出的H6拓扑在功率传输模态时,进网电流半个工频周期流过3支开关管,而另半个工频周期流过2支开关管,故相对于H5拓扑,降低了通态损耗,有利于热应力均衡,且仍满足续流阶段光伏电池输出端与电网脱离的要求。详细分析拓扑的工作原理,并推论给出H6非隔离光伏并网逆变器的其它3种拓扑结构;比较分析了H5拓扑、Heric拓扑和H6拓扑的损耗和成本。通过1kW通用样机平台对比验证了上述3种拓扑的效率和共模特性。实验结果表明,H6拓扑的变换效率高于H5拓扑、但略低于Heric拓扑,共模特性优于Heric拓扑、但略劣于H5拓扑。
Non-isolated inverter topologies have obtained more attentions in photovoltaic (PV) generation system since they are featured by higher efficiency and lower cost. In order to meet the safety requirement for the non-isolated grid-tied PV inverter, the common-mode leakage current is required to be carefully tackled due to the absence of the transformer. A H6 non-isolated full bridge PV grid-connected inverter is proposed to meet the limit for common-mode leakage current in grid-tied PV generation systems, as shown in Fig. 1.