由于供热系统中用户换热站没有有效的调节装置和根据热负荷的变化进行实时调节的自控系统,影响了乌鲁木齐市的集中供热系统整体效果.根据控制策略分级执行的原则将换热站系统分为:就地监控系统、通信系统以及中心控制系统.对换热站整体结构以及监控系统方案进行了设计,并应用于实际,运行情况良好.
The heating system of heat exchange station without user adjustment device for automatic control system of effective and real - time adjustment according to the change of the heat load, the quality of the central heating system in Urumqi city. According to the strategy of classification the implementation of the principle of control system is divided into: in situ monitoring system, communication system and central control system. The overall structure and the heat exchange station monitoring system was designed, and applied to the actual, running in good condition.