中文摘要:

·AIM: To compare posterior capsule opacification(PCO)degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens(IOL)(570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL(Sensar AR40 e,AMO) in diabetic patients.· METHODS: Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification(EPCO) 2000 image-analysis software at 1, 6, 12, and 24 mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared.·RESULTS: There was not any statistically significant difference in PCO scores between Rayner C-flex 570 C group and Sensar AR40 e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24 mo follow-up.·CONCLUSION: For diabetic patients, Rayner 570 C Cflex and Sensar AR40 e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention.

英文摘要:

·AIM: To compare posterior capsule opacification(PCO)degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens(IOL)(570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL(Sensar AR40 e,AMO) in diabetic patients.· METHODS: Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification(EPCO) 2000 image-analysis software at 1, 6, 12, and 24 mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared.·RESULTS: There was not any statistically significant difference in PCO scores between Rayner C-flex 570 C group and Sensar AR40 e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24 mo follow-up.·CONCLUSION: For diabetic patients, Rayner 570 C Cflex and Sensar AR40 e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《国际眼科杂志:英文版》
  • 主管单位:
  • 主办单位:中华医学会西安分会
  • 主编:
  • 地址:陕西省西安市
  • 邮编:710054
  • 邮箱:
  • 电话:
  • 国际标准刊号:ISSN:2222-3959
  • 国内统一刊号:ISSN:
  • 邮发代号:
  • 获奖情况:
  • 国内外数据库收录:
  • 美国化学文摘(网络版),荷兰文摘与引文数据库,荷兰医学文摘,美国生物医学检索系统,美国科学引文索引(扩展库),瑞典开放获取期刊指南
  • 被引量:25