可调焦离轴三反光学系统的装调
  • ISSN号:1004-924X
  • 期刊名称:《光学精密工程》
  • 时间:0
  • 分类:O435.2[机械工程—光学工程;理学—光学;理学—物理]
  • 作者机构:[1]中国科学院西安光学精密机械研究所,陕西西安710119, [2]中国科学院研究生院,北京100049
  • 相关基金:国家自然科学基金资助项目(No.40805013)
中文摘要:

针对离轴反射光学系统的精密装调问题,提出了一种高精度空间交互测量以及基准传递系统,可实现调焦角度与系统光轴的高精度角度定位。该系统口径为450mm,可实现0.5km至无穷远的调焦,调焦角度精确定位后,只需调整无穷远处离轴三反光学系统的波像差满足要求,即可保证系统各个调焦位置处的波像差均满足设计要求,大大提高了装调效率。装调实验结果表明,无穷远处系统的波像差结果为0.09λ,1.5km处系统的波像差为0.1λ,2.5km处系统的波像差为0.11λ,0.5km处系统的波像差为0.2λ,均优于设计要求。

英文摘要:

A space interactive measurement and datum transmission system with high accuracy was proposed,aiming at precise alignment problem of off-axis reflective optical system.Therefore the highly accurate angle location of focusing angle and systemic optical axis was realized.The diameter of the system was 450 mm,and focus-adjustable range was from 0.5km to infinity.After accurate positioning of focusing angles,only wave aberration of off-axis three-mirror optical system in infinite position needed to be adjusted to satisfy requirements,and the wave aberrations of all focus position in the system could be guaranteed to accord with design requirements,thus improving adjustment efficiency greatly.The experimental results show that the wave aberrations of the system in infinite position,1.5km,2.5km and 0.5km are 0.1λ,0.11λ,0.5km and 0.2λrespectively,which are all better than design requirements.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《光学精密工程》
  • 北大核心期刊(2011版)
  • 主管单位:中国科学院
  • 主办单位:中国科学院长春光学精密机械与物理研究所 中国仪器仪表学会
  • 主编:曹健林
  • 地址:长春市东南湖大路3888号
  • 邮编:130033
  • 邮箱:gxjmgc@sina.com;gxjmgc@ciomp.ac.cn
  • 电话:0431-86176855 84613409传
  • 国际标准刊号:ISSN:1004-924X
  • 国内统一刊号:ISSN:22-1198/TH
  • 邮发代号:12-166
  • 获奖情况:
  • 三次获得“百种中国杰出学术期刊”,2006年获得中国科协择优支持基金,2007年获“吉林省新闻出版精品期刊奖”,2008年获“中国精品科技期刊”,2012年《光学精密工程》看在的3篇论文获得中国百...,第三届中国出版政府奖提名奖
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国剑桥科学文摘,英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:22699