位置:成果数据库 > 期刊 > 期刊详情页
重组pEGFP-C2-FOXC1-C真核表达质粒的构建与表达
  • ISSN号:1006-8147
  • 期刊名称:天津医科大学学报
  • 时间:2012
  • 页码:148-150+154
  • 分类:R778.11[医药卫生—眼科;医药卫生—临床医学]
  • 作者机构:[1]天津医科大学眼科医院,300384, [2]北京同仁医院验光配镜中心
  • 相关基金:国家自然科学基金(81100646);天津市科委自然科学基金(11JCY,BJC26000)
  • 相关项目:CD4+CD25+调节性T细胞在干眼发病的免疫调节机制及抗CD3抗体的免疫治疗
中文摘要:

目的探讨硬性透气性角膜接触镜(RGPCL)控制青少年近视合并高度散光的远期效果。设计回顾性病例系列。研究对象戴用RGPCL随诊5年的近视合并高度散光(≥-2.50 D)患者48例(69眼),平均年龄(15.2±1.5)岁;戴用框架眼镜随诊5年的近视合并高度散光(≥-2.50 D)患者51例(102眼),平均年龄(15.3±1.6)岁。方法两组患者配镜前后均经复方托呲卡胺散瞳验光。检查二种矫正方法组患者的矫正视力,电脑验光仪检测角膜水平曲率半径、垂直曲率半径和平均曲率半径。两组患者连续5年观察上述数据变化,并对初诊时及第5年随诊的结果进行统计分析。主要指标球镜度、柱镜度、戴镜视力、角膜水平曲率半径值、角膜垂直曲率半径值、角膜平均曲率半径值。结果第5年时,RGPCL组和框架组最佳矫正视力分别为(0.99±0.41)和(0.74±0.13)。第5年与初诊时比较,RGPCL组和框架组球镜度分别增加(0.623±1.067)D、(2.018±1.461)D,两组比较差异有统计学意义(P=0.000);RGPCL组柱镜度减少(0.696±0.694)D,框架组柱镜度增加(0.417±0.574)D,两组比较差异有统计学意义(P=0.000)。RGPCL组戴镜5年后角膜水平曲率半径、角膜垂直曲率半径、角膜平均曲率半径平均增加量分别为(0.046±0.106)mm、(0.189±0.184)mm、(0.119±0.131)mm。结论 5年的随访结果显示,硬性透气性角膜接触镜对青少年近视合并高度散光患者的近视、散光发展有一定的控制作用。

英文摘要:

Objective To investigate the long term clinical effects of rigid gas permeable contact lens(RGPCL) control on adolescent myopia combined with high astigmatism. Design Retrospective case series. Participants 48 patients(69 eyes), with a mean age of(15.2±1.5) years with myopia combined with high astigmatism( ≥-2.50 D) were fitted with RGPCL and followed up for 5 years. 51 patients(102 eyes), with a mean age of(15.3±1.6) years with myopia combined with high astigmatism( ≥-2.50 D) were fitted with spectacles and followed up for 5 years. Methods For RGPCL group, after using tropicamide phenylephrine eye drops, the ocular refraction, corrected visual acuity and the radius of corneal curvature changes were observed for 5 years. For spectacles group, after usingtropicamide phenylephrine eye drops, the ocular refraction, corrected visual acuity were observed for 5 years. The differences of the average sphere diopter, cylinder diopter, and corrected visual acuity were compared between RGPCL group and spectacle group. Main Outcome Measures The average sphere diopter, cylinder diopter, corrected visual acuity, average horizontal radius, average vertical radius, average radius of corneal curvature. Results Corrected visual acuity was(0.99±0.41) after wearing RGPCL for 5 years. Corrected visual acuity was(0.74±0.13) after wearing spectacles for 5 years. During the 5-year follow up, the average sphere diopter increased significantly less in RGPCL group than in spectacle group(0.623±1.067 D vs. 2.018±1.461 D)(P〈0.0001). More strikingly, the cylinder diopter decreased 0.696±0.694 D in RGPCL group, which is significantly different from spectacle group(increased 0.417±0.574 D)(P〈0.0001). The average horizontal radius, average vertical radius, average radius of corneal curvature increased(0.046 ±0.106)mm,(0.189±0.184)mm,(0.119±0.131)mm after wearing RGPCL for 5 years. Conclusion Myopia and astigmatism progression can be controlled by wearing RGPCL.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《天津医科大学学报》
  • 主管单位:天津市教育委员会
  • 主办单位:天津医科大学
  • 主编:尚永丰
  • 地址:天津市和平区气象台路22号
  • 邮编:300070
  • 邮箱:xuebao@tijnu.edu.cn
  • 电话:022-83336719 83336803
  • 国际标准刊号:ISSN:1006-8147
  • 国内统一刊号:ISSN:12-1259/R
  • 邮发代号:
  • 获奖情况:
  • 1999年被评为天津市高校学报一等奖,1999年被评为天津市期刊评估一级期刊
  • 国内外数据库收录:
  • 被引量:10138