利用涂布五氟苄基羟胺(PFBHA)的Tenax-TA作为固体吸附剂,采取主动采样的方式采集大气中羰基化合物,再经溶剂洗脱和氮吹浓缩后用气相色谱/质谱(GC/MS)分析,成功检测到14种单羰基化合物和2种二羰基化合物(乙二醛与甲基乙二醛).研究表明:在吸附剂的装载量为50mg的前提下,当衍生剂的涂布量为260nmol,采集流速为50mL·min^-1时,采集效果最佳.羰基化合物的检测限、平行样的相对标准偏差和样品的加标回收率范围分别为0.54~3.83ng·m^-3、1.0%~14.2%、89.2%~113.8%.该方法在实际大气样品中合适的采样时间为0.5~8.0h.利用此法对上海市宝山区大气中羰基化合物进行了检测,成功检测到16种羰基化合物,且具有明显的日变化趋势.
A method for detecting 14 mono- and 2 dicarbonyl compounds in one run was established. The carbonyls were collected on solid sorbenl (Tenax-TA) coated with derivating agent O- (2,3,4,5,6-Pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA) , followed by solvent desorption, concentration and gas chromatography/mass spectrometry analysis. The coating amount and the sampling flow rate were optimized. The results showed that the best collection efficiency was achieved when the coating amount was 260 nmol and the sampling flow rate was 50 mL·min^-1 for a loading of 50 mg Tenax-TA. The limits of detection were in the range of 0.54 - 3.83 ng·m^-3. The relative standard deviations of parallel samples were 1.0% - 14.2% and the recoveries of the spiked standards were 89. 2% - 113.8%. The time resolution could be 30 min to 8 h for ambient air sampling. The method was successfully applied to measure 16 mono- and dicarbonyls in the ambient air of Baoshan District of Shanghai and the detected carbonyls have significant diurnal varialion.