在“强光一号”装置驱动电流峰值1.4-2.1MA、上升时间80-100ns条件下,研究了不同丝阵直径、丝数及丝直径的钨丝阵负载Z箍缩等离子体的辐射特性.用自行研制的测试系统对等离子体辐射参数进行了诊断.实验获得的最大X射线总能量为34kJ,最大峰值功率为1.28TW.得到了一些关于钨丝阵Z箍缩等离子体辐射特性的规律性认识.
Experimental study on plasma radiation characteristics of W wire array Z pinch with different initial parameters performed on Qiangguang- Ⅰ pulsed power generator of 1.4-2.1MA current with 80-100ns rise time is reported. The generator configuration and the diagnostic system for the experiments are briefly described. The total X-ray energy and peak power have been measured, and the maximum of X-ray energy and peak power are 34kJ and 1.28TW, respectively. In additional, the main results and conclusions are discussed also.