位置:成果数据库 > 期刊 > 期刊详情页
氯离子浓度对混凝土电通量试验中测试指标的影响
  • ISSN号:1002-3550
  • 期刊名称:《混凝土》
  • 时间:0
  • 分类:TU528.01[建筑科学—建筑技术科学]
  • 作者机构:[1]南京工业大学,江苏南京210009, [2]江苏省建筑科学研究院,江苏南京210009
  • 相关基金:西部交通建设科技项目(2006ZB12)
中文摘要:

研究了不同NaCl溶液浓度对复合双掺粉煤灰、矿渣混凝土的ASTM C1202测试指标的影响,采用ASTM C1202方法测试了(1%、3%、5%、10%)四种NaCl溶液浓度下粉煤灰和矿渣复合双掺混凝土120d龄期的6h通电量、渗透深度和平均电流。研究结果表明:混凝土的6h通电量、渗透深度和平均电流都随着NaCl溶液浓度的增大而增加,且不同NaCl溶液浓度下渗透深度、平均电流与6h通电量相关性较好,可以考虑用渗透深度和平均电流作为混凝土抗氯离子渗透性评价指标。

英文摘要:

The effects of ASTM C 1202 test parameters of concrete which mixes with fly-ash and slag by the different concentration of NaCl solution are studied.The charge passed 6 hours, penetration depth of chloride ions and average current of concrete mixes with fly-ash and slag were tested according to ASTM C1202 at age of 120 d in different four kinds NaCI solution.The result indicates that,the charge passed 6 hours, penetration depth of chloride ions and average current of concrete all increase along with increasing of concentration of NaCl solution.And the correlation between penetration depth of chloride ions, average current and the charge passed 6 hours are good for the different concentration of NaCl solution.Penetration depth of chloride ions and average current can be used as evaluating parameter for chloride ions penetration resistant ability of concrete which mixes with fly ash and slag.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《混凝土》
  • 北大核心期刊(2011版)
  • 主管单位:中华人民共和国住房和城乡建设部
  • 主办单位:中国建筑东北设计研究院有限公司
  • 主编:
  • 地址:沈阳市和平区光荣街65号中国建筑东北设计研究院有限公司
  • 邮编:110006
  • 邮箱:hntbjb@vip.163.com
  • 电话:024-62123865 83860449
  • 国际标准刊号:ISSN:1002-3550
  • 国内统一刊号:ISSN:21-1259/TU
  • 邮发代号:8-110
  • 获奖情况:
  • 中国建筑科学核心期刊,全国中文核心期刊
  • 国内外数据库收录:
  • 美国化学文摘(网络版),美国剑桥科学文摘,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:24168