位置:成果数据库 > 期刊 > 期刊详情页
Soft X-ray PHA Diagnostic for the Electron Temperature Measurements on EAST
  • ISSN号:1009-0630
  • 期刊名称:《等离子体科学与技术:英文版》
  • 时间:0
  • 分类:TL631.24[核科学技术—核技术及应用] TN402[电子电信—微电子学与固体电子学]
  • 作者机构:[1]Southwestern Institute of Physics, Chengdu 610041, China
  • 相关基金:supported by National Natural Science Foundation of China (Nos. 10775041 and 10675124). The authors wish to thank the team of HL-2A oper- ation, professors YUAN Baoshan, ZHENG Yinjia and LIU Dequan, for their help.
中文摘要:

The plasma facing component in HL-2A has been damaged seriously after disruption,and for this reason its operation is suspended for maintenance.The experimental phenomena and plasma configurations,calculated by the current filament code(CF-code) using the plasma parameters measured by diagnostics and the signals of the magnetic probes,confirm that the first wall is damaged by the synergetic effects of runaway electrons and disruption induced by a vertical displacement event(VDE).When the plasma column is displaced upward/downward,the strong runaway electrons normally hit the baffle plate of the MP 3 or MP 1 coil in the upper and lower divertor during the disruption,causing the baffle plates to be holed and wrinkled by the energetic runaway current,and water(for cooling or heating the baffle plates) to leak into the vacuum vessel.Another disastrous consequence is that bellows underlying the baffle plate and outside the coil of MP 3 for connecting two segments of the jacket casing pipe are punctured by arcing.The arc may be part of the halo current that forms a complete circuit.The experimental phenomena are indirect but compelling evidence for the existence of a halo current during the disruption and VDE,though the halo current has not been measured by the diagnostics in the HL-2A tokamak.

英文摘要:

The plasma facing component in HL-2A has been damaged seriously after disruption, and for this reason its operation is suspended for maintenance. The experimental phenomena and plasma configurations, calculated by the current filament code (CF-code) using the plasma parameters measured by diagnostics and the signals of the magnetic probes, confirm that the first wall is damaged by the synergetic effects of runaway electrons and disruption induced by a vertical displacement event (VDE). When the plasma column is displaced upward/downward, the strong runaway electrons normally hit the baffle plate of the MP3 or MP1 coil in the upper and lower divertor during the disruption, causing the baffle plates to be holed and wrinkled by the energetic runaway current, and water (for cooling or heating the baffle plates) to leak into the vacuum vessel. Another disastrous consequence is that bellows underlying the baffle plate and outside the coil of MP3 for connecting two segments of the jacket casing pipe are punctured by arcing. The arc may be part of the halo current that forms a complete circuit. The experimental phenomena are indirect but compelling evidence for the existence of a halo current during the disruption and VDE, though the halo current has not been measured by the diagnostics in the HL-2A tokamak.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《等离子体科学与技术:英文版》
  • 主管单位:中国科学院 中国科协
  • 主办单位:中国科学院等离子体物理研究所 中国力学学会
  • 主编:万元熙、谢纪康
  • 地址:合肥市1126信箱
  • 邮编:230031
  • 邮箱:pst@ipp.ac.cn
  • 电话:0551-5591617 5591388
  • 国际标准刊号:ISSN:1009-0630
  • 国内统一刊号:ISSN:34-1187/TL
  • 邮发代号:
  • 获奖情况:
  • 国内外数据库收录:
  • 美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国剑桥科学文摘,美国科学引文索引(扩展库),英国科学文摘数据库
  • 被引量:89