中文摘要:

We propose a systematic ECG quality classification method based on a kernel support vector machine(KSVM) and genetic algorithm(GA) to determine whether ECGs collected via mobile phone are acceptable or not. This method includes mainly three modules, i.e., lead-fall detection, feature extraction, and intelligent classification. First, lead-fall detection is executed to make the initial classification. Then the power spectrum, baseline drifts, amplitude difference, and other time-domain features for ECGs are analyzed and quantified to form the feature matrix. Finally, the feature matrix is assessed using KSVM and GA to determine the ECG quality classification results. A Gaussian radial basis function(GRBF) is employed as the kernel function of KSVM and its performance is compared with that of the Mexican hat wavelet function(MHWF). GA is used to determine the optimal parameters of the KSVM classifier and its performance is compared with that of the grid search(GS) method. The performance of the proposed method was tested on a database from PhysioNet/Computing in Cardiology Challenge 2011, which includes 1500 12-lead ECG recordings. True positive(TP), false positive(FP), and classification accuracy were used as the assessment indices. For training database set A(1000 recordings), the optimal results were obtained using the combination of lead-fall, GA, and GRBF methods, and the corresponding results were: TP 92.89%, FP 5.68%, and classification accuracy 94.00%. For test database set B(500 recordings), the optimal results were also obtained using the combination of lead-fall, GA, and GRBF methods, and the classification accuracy was 91.80%.

英文摘要:

We propose a systematic ECG quality classification method based on a kernel support vector machine(KSVM) and genetic algorithm(GA) to determine whether ECGs collected via mobile phone are acceptable or not. This method includes mainly three modules, i.e., lead-fall detection, feature extraction, and intelligent classification. First, lead-fall detection is executed to make the initial classification. Then the power spectrum, baseline drifts, amplitude difference, and other time-domain features for ECGs are analyzed and quantified to form the feature matrix. Finally, the feature matrix is assessed using KSVM and GA to determine the ECG quality classification results. A Gaussian radial basis function(GRBF) is employed as the kernel function of KSVM and its performance is compared with that of the Mexican hat wavelet function(MHWF). GA is used to determine the optimal parameters of the KSVM classifier and its performance is compared with that of the grid search(GS) method. The performance of the proposed method was tested on a database from PhysioNet/Computing in Cardiology Challenge 2011, which includes 1500 12-lead ECG recordings. True positive(TP), false positive(FP), and classification accuracy were used as the assessment indices. For training database set A(1000 recordings), the optimal results were obtained using the combination of lead-fall, GA, and GRBF methods, and the corresponding results were: TP 92.89%, FP 5.68%, and classification accuracy 94.00%. For test database set B(500 recordings), the optimal results were also obtained using the combination of lead-fall, GA, and GRBF methods, and the classification accuracy was 91.80%.

同期刊论文项目
期刊论文 13 会议论文 4 专利 2
同项目期刊论文
期刊信息
  • 《中国通信:英文版》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国通信学会
  • 主编:刘复利
  • 地址:北京市东城区广渠门内大街80号6层608
  • 邮编:100062
  • 邮箱:editor@ezcom.cn
  • 电话:010-64553845
  • 国际标准刊号:ISSN:1673-5447
  • 国内统一刊号:ISSN:11-5439/TN
  • 邮发代号:2-539
  • 获奖情况:
  • 国内外数据库收录:
  • 被引量:187