位置:成果数据库 > 期刊 > 期刊详情页
A sensitive charge scanning probe based on silicon single electron transistor
  • ISSN号:1674-4926
  • 期刊名称:《半导体学报:英文版》
  • 时间:0
  • 分类:TN32[电子电信—物理电子学] O441.1[理学—电磁学;理学—物理]
  • 作者机构:[1]Engineering Research Center of IoT Technology Applications (Ministry of Education), Department of Electronic Engineering,Jiangnan University, Wuxi 214122, China, [2]Key Laboratory of Nanodevices and Applications, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy ofSciences, Suzhou 215123, China
  • 相关基金:Project supported by the Instrument Developing Project of the Chinese Academy of Sciences(No.YZ201152); the National Natural Science Foundation of China(No.11403084); the Fundamental Research Funds for Central Universities(Nos.JUSRP51510,JUDCF12032); the Graduate Student Innovation Program for Universities of Jiangsu Province(No.CXLX12_0724)
中文摘要:

Single electron transistors(SETs) are known to be extremely sensitive electrometers owing to their high charge sensitivity. In this work, we report the design, fabrication, and characterization of a silicon-on-insulatorbased SET scanning probe. The fabricated SET is located about 10 m away from the probe tip. The SET with a quantum dot of about 70 nm in diameter exhibits an obvious Coulomb blockade effect measured at 4.1 K. The Coulomb blockade energy is about 18 me V, and the charge sensitivity is in the order of 10-(5)–10(-3)e/Hz1/2. This SET scanning probe can be used to map charge distribution and sense dynamic charge fluctuation in nanodevices or circuits under test, realizing high sensitivity and high spatial resolution charge detection.

英文摘要:

Single electron transistors(SETs) are known to be extremely sensitive electrometers owing to their high charge sensitivity. In this work, we report the design, fabrication, and characterization of a silicon-on-insulatorbased SET scanning probe. The fabricated SET is located about 10 m away from the probe tip. The SET with a quantum dot of about 70 nm in diameter exhibits an obvious Coulomb blockade effect measured at 4.1 K. The Coulomb blockade energy is about 18 me V, and the charge sensitivity is in the order of 10~-(5)–10(~-3)e/Hz~(1/2). This SET scanning probe can be used to map charge distribution and sense dynamic charge fluctuation in nanodevices or circuits under test, realizing high sensitivity and high spatial resolution charge detection.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《半导体学报:英文版》
  • 中国科技核心期刊
  • 主管单位:中国科学院
  • 主办单位:中国电子学会 中国科学院半导体研究所
  • 主编:李树深
  • 地址:北京912信箱
  • 邮编:100083
  • 邮箱:cjs@semi.ac.cn
  • 电话:010-82304277
  • 国际标准刊号:ISSN:1674-4926
  • 国内统一刊号:ISSN:11-5781/TN
  • 邮发代号:2-184
  • 获奖情况:
  • 90年获中科院优秀期刊二等奖,92年获国家科委、中共中央宣传部和国家新闻出版署...,97年国家科委、中共中央中宣传部和国家新出版署三等奖,中国期刊方阵“双效”期刊
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国剑桥科学文摘,英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:7754