扫描型X射线荧光显微分析仪测定汽车零部件及内饰材料中铅、镉、汞、铬和溴
  • ISSN号:1008-6145
  • 期刊名称:《化学分析计量》
  • 时间:0
  • 分类:O657.3[理学—分析化学;理学—化学]
  • 作者机构:[1]南京出入境检验检疫局,南京210046
  • 相关基金:江苏出入境检验检疫局科技计划项目(2015KJ13)
中文摘要:

建立扫描型X射线荧光显微分析仪测定汽车零部件及内饰材料中铅、镉、汞、铬和溴等元素的方法。通过改变测量条件与测量方式选择最佳试验方法,采用成像图判断样品中是否存在目标元素。结果表明,5种元素的含量在0~300mg/kg范围内与荧光强度成良好的线性关系,相关系数均大于0.993,样品加标回收率为82.3%~106.0%,测定结果的相对标准偏差为2.86%~6.63%(n=6)。该方法简单、快速,测定结果准确、可靠,适用于汽车零部件和内饰材料中有毒有害物质的筛选。

英文摘要:

A method for determination of lead,cadmium,mercury,chromium and bromine element in automobile components and interior materials was established by scan x-ray analytical microscope.The optimum test method was selected by changing measuring conditions and methods,and the toxic and harmful substances were detected by imaging map.The result showed that the content of5elements had good linearity with the fluorescence intensity in the range of0-300mg/kg with the correlation coefficient more than0.993,the sample recoveries were82.3%-106.0%,and the relative standard deviations of the results were2.86%-6.63%(n=6).The method is simple and rapid,accurate and reliable,and it is suitable for screening toxic and harmful substances in automobile components and interior materials.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《化学分析计量》
  • 中国科技核心期刊
  • 主管单位:
  • 主办单位:中国兵器工业第五三研究所(国防科工委化学计量一级站)
  • 主编:王金立
  • 地址:山东济南市天桥区无影山田庄东路3号
  • 邮编:250031
  • 邮箱:85878224@163.com
  • 电话:0531-85878132
  • 国际标准刊号:ISSN:1008-6145
  • 国内统一刊号:ISSN:37-1315/O6
  • 邮发代号:24-138
  • 获奖情况:
  • 国内外数据库收录:
  • 被引量:6647