位置:成果数据库 > 期刊 > 期刊详情页
飞秒激光小切口角膜基质内透镜取出术与飞秒激光LASIK术后高阶像差改变的对比研究
  • ISSN号:0412-4081
  • 期刊名称:中华眼科杂志
  • 时间:2015
  • 页码:193-201
  • 分类:R779.63[医药卫生—眼科;医药卫生—临床医学]
  • 作者机构:天津市眼科医院天津科学与视觉科学重电试验室、天津市眼科研究所、天津医科大学眼科临床学院,300020
  • 相关基金:国家自然科学基金(81170873);天津市卫生局攻关项目(10KG109)
  • 相关项目:利用个体化眼模型研究角膜屈光手术后色差与视觉不良症状的关联机制
中文摘要:

目的:评估和对比飞秒激光小切口角膜基质透镜取出术(SMILE)和飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK)角膜前表面非球面性的变化特点。方法病例对照研究。收集自愿选择行SMILE手术的屈光不正患者45例作为试验组,另收集行FS-LASIK的屈光不正患者33例作为对照组。均选右眼为研究眼,于术前、术后1周及1、3、6个月分别测量患者角膜前表面6、7、8、9 mm直径范围下的非球面系数Q值,对两组间的Q值变化特点进行对比分析。分析Q值变化量与中央切削深度(CCD)的相关关系。两组间一般资料及术前Q值的比较采用独立样本t检验,Q值整体分析采用方差分析。结果术后1周时角膜前表面Q值,SMILE组分别为:0.85±0.31、0.80±0.28、0.69±0.25、0.51±0.23;FS-LASIK组分别为:1.13±0.56、1.01±0.47、0.80±0.39、0.51±0.31。各直径范围下手术前后不同时间所测Q值差异均有统计学意义(P〈0.05),且手术方式与时间之间均存在交互效应;其中6和7mm直径时不同手术方式间差异也有统计学意义(P〈0.05)。两组间术后1周与术前的Q值差值(ΔQ)在6、7mm直径范围下差异有统计学意义(P6mm=0.004,P7mm=0.014)。SMILE组帽直径较FS-LASIK组小;CCD较FS-LASIK组大。各直径范围下ΔQ与帽/瓣直径均无线性关系。各直径范围下ΔQ与CCD均呈线性关系(P〈0.05),且FS-LASIK组相关程度优于SMILE组。结论 SMILE与FS-LASIK均会使角膜前表面的Q值由负变正。然而,SMILE对角膜前表面非球面性的影响较FS-LASIK小。(中华眼科杂志,2016,52:681-685)

英文摘要:

Objective To evaluate and compare the anterior corneal asphericity after small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) . Methods In this case-control study, 45 subjects who underwent SMILE operation comprised the study group, and 33 subjects with FS-LASIK operation comprised the control group. The asphericity coefficient Q-value of the right eyes in both groups was measured at diameters of 6, 7, 8 and 9 mm, respectively, before surgery and at 1 day, 1 week, 1 month and 6 months following surgery. The correlation between the variation of Q-value and the central cutting depth was analyzed. Results The Q-value of anterior corneal surface was 0.85 ± 0.31, 0.80 ± 0.28, 0.69 ± 0.25 and 0.51 ± 0.23 after SMILE, and 1.13 ± 0.56, 1.01 ± 0.47, 0.80 ± 0.39 and 0.51 ± 0.31 after FS-LASIK at 1 week. In both groups, the Q-value was significantly different before and after surgery(P〈0.05);there were interaction effects between the operation method and time;the difference between the two groups at 6-mm and 7-mm diameters was statistically significant (P〈0.05). The variation of the Q-value before and after operation(ΔQ)showed significant difference(P6mm=0.004,P7mm=0.014)between the two groups at 6-mm and 7-mm diameters. The cap diameter of the SMILE group was smaller than that of the FS-LASIK group, but the cutting depth was larger. There was no correlation between ΔQ and the cap/disc diameter. It showed a linear relationship(P〈0.05)betweenΔQ and the central cutting depth at all examined diameters in the two groups, and the relation degree in the FS-LASIK group was superior to the SMILE group. Conclusions Both SMILE and FS-LASIK operations can change the negative Q-value of the anterior corneal surface to the positive. The impact of SMILE on the asphericity is smaller than that of FS-LASIK.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《中华眼科杂志》
  • 中国科技核心期刊
  • 主管单位:中国科协
  • 主办单位:中华医学会
  • 主编:
  • 地址:北京市东四西大街42号
  • 邮编:100710
  • 邮箱:cjo@cma.org.cn
  • 电话:010-85158241
  • 国际标准刊号:ISSN:0412-4081
  • 国内统一刊号:ISSN:11-2142/R
  • 邮发代号:2-60
  • 获奖情况:
  • 1992年荣获国家科委全国优秀科技期刊评比三等奖,1996年荣获中国科协第二届全国优秀学术期刊二等奖,中国期刊方阵“双效”期刊
  • 国内外数据库收录:
  • 美国化学文摘(网络版),荷兰文摘与引文数据库,美国生物医学检索系统,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:33530