碳纳米管/TiO2薄膜固定酶的生物传感器及电催化氧化H2O2的研究
  • ISSN号:1000-0720
  • 期刊名称:《分析试验室》
  • 时间:0
  • 分类:O657.1[理学—分析化学;理学—化学]
  • 作者机构:[1]浙江警察学院,杭州310053, [2]浙江大学化学系,杭州310028
  • 相关基金:国家自然壳学基金(29975024,20275034)项目资助
中文摘要:

采用酸性溶胶法在碳纳米管上负载纳米TiO2颗粒,并制备了CNT-TiO2薄膜固定辣根过氧化物酶的生物传感器。研究了该生物传感器在磷酸盐缓冲溶液中对H2O2的电催化氧化作用及实验条件的影响。结果表明该生物传感器对H2O2表现出良好的电催化性能,在最佳实验条件下,对H2O2检测的线性范围为:4.2×10^-7mol/L~3.2×10^-3mol/L。检出限为:7.22×10^-8mol/L。

英文摘要:

The acid sol method was used for decorating TiO2 nanoparticles onto carbon nanotube surface. A gold elec- trode modified with TiO2-CNT was prepared. An amperometric horseradish peroxidase biosensor was prepared by immobilization of HRP in TiO2-CNT thin film on the gold electrode. The electrochemical oxidation of hydrogen peroxide was studied on this biosensor. The experiments showed that the nanoparticles could enhance the catalytic activity of immobilized enzyme. The linear detection range was 4.2 × 10^-7 mol/L - 3.2 × 10^-3 mol/L and the detection limit was 7.22 × 10^-8 mol/L.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《分析试验室》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:北京有色金属研究总院 中国有色金属协会
  • 主编:屠海令
  • 地址:北京新街口外大街2号
  • 邮编:100088
  • 邮箱:analysislab@263.net
  • 电话:010-82013328
  • 国际标准刊号:ISSN:1000-0720
  • 国内统一刊号:ISSN:11-2017/TF
  • 邮发代号:82-431
  • 获奖情况:
  • 综合性分析化学刊物,中文核心期刊
  • 国内外数据库收录:
  • 美国化学文摘(网络版),美国剑桥科学文摘,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:25540