Preparation of dendritic bismuth film electrodes and their application for detection of trace Pb (Ⅱ) and Cd (Ⅱ)
  • ISSN号:1004-9541
  • 期刊名称:《中国化学工程学报:英文版》
  • 时间:0
  • 分类:O657.1[理学—分析化学;理学—化学] TS207.51[轻工技术与工程—食品科学;轻工技术与工程—食品科学与工程]
  • 作者机构:[1]College of Chemical Engineering, North China University of Science and Technology, Tangshan 063009, China, [2]Hebei Province Key Laboratory of InorgaNic and Non-metal Materials, Tangshan 063009, China
  • 相关基金:Supported by the National Natural Science Foundation of China (51472073, 51201058).
中文摘要:

In this paper,dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates.The electrode prepared using a large applied current density showed an increased internal electroactive area and a significantly improved electrochemical performance.The analytical utility of the prepared dendritic Bi film electrodes for the determination of Pb(Ⅱ)and Cd(Ⅱ)in the range of 5–50 μg·L-1were presented in combination with square wave stripping voltammetry in model solution.Compared with non-porous Bi film electrode,the dendritic Bi film electrode exhibited higher sensitivity and lower detection limit.The prepared Bi film electrode with dendritic structure was also successfully applied to real water sample analysis.

英文摘要:

In this paper, dendritic Bi film electrodes with porous structure had successfully been prepared on glassy carbon electrode using a constant current electrolysis method based on hydrogen bubble dynamic templates. The electrode prepared using a large applied current density showed an increased internal electroactive area and a significantly improved electrochemical performance. The analytical utility of the prepared dendritic Bi film electrodes for the determination of Pb (Ⅱ) and Cd (Ⅱ) in the range of 5-50 μg · L- 1 were presented in combination with square wave stripping voltammetry in model solution. Compared with non-porous Bi film electrode, the dendrit- ic Bi film electrode exhibited higher sensitivity and lower detection limit. The prepared Bi film electrode with dendritic structure was also successfully applied to real water sample analysis.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《中国化学工程学报:英文版》
  • 中国科技核心期刊
  • 主管单位:中国科协
  • 主办单位:中国化学工业与化学工程学会
  • 主编:
  • 地址:北京东城区青年湖路13号
  • 邮编:100011
  • 邮箱:cjche@cip.com.cn
  • 电话:010-64519487/88
  • 国际标准刊号:ISSN:1004-9541
  • 国内统一刊号:ISSN:11-3270/TQ
  • 邮发代号:
  • 获奖情况:
  • 1998年化工系统优秀信息成果一等奖,中国期刊方阵“双效”期刊
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国剑桥科学文摘,美国科学引文索引(扩展库),英国高分子图书馆,日本日本科学技术振兴机构数据库,中国中国科技核心期刊
  • 被引量:385