迭代模型重组设置对不同辐射剂量下肝脏增强CT图像噪声及质量的影响
  • ISSN号:1005-1201
  • 期刊名称:《中华放射学杂志》
  • 时间:0
  • 分类:R814.42[医药卫生—影像医学与核医学;医药卫生—放射医学;医药卫生—临床医学]
  • 作者机构:[1]广东省医学科学院广东省人民医院放射科,广州510080, [2]广州市第一人民医院放射科, [3]飞利浦中国影像研究院
  • 相关基金:国家自然科学基金(81271569,81271654)
中文摘要:

目的 探讨迭代模型重组技术(IMR)的不同重组设置对不同辐射剂量下肝脏增强CT噪声及图像质量的影响.方法 前瞻性收集因病情需要行肝脏增强CT检查的患者纳入研究,将患者按照数字表法随机分为常规组和低剂量组2组.常规组29例,低剂量组25例.患者均行上腹部平扫和肝脏3期增强扫描.常规组门静脉期管电压120 kV,管电流250 mAs;低剂量组门静脉期管电压80 kV,管电流500 mAs.将门静脉期原始数据进行传统滤波反投影法(FBP)重组和IMR重组,IMR重组得到不同重组水平(L1~ L3)的体部常规重组(BR)和体部软组织重组(BST)图像,分别为L1BR、L2BR、L3BR、L1BST、L2BST、L3BST.对各组图像进行主观评价[包括低对比分辨率(LCD)评分、图像失真(ID)评分和诊断信心(DC)评分]、客观评价[包括肝脏噪声、信噪比(SNR)和对比噪声比(CNR)],并记录有效辐射剂量.采用FriedmanH检验和随机区组方差分析比较各组图像的主观和客观评价指标,采用两独立样本t检验比较常规组和低剂量组的辐射剂量.结果 常规组图像中,LCD评分L2BST组、L3BST组较高,中位数均为4分;ID评分L3BST、L2BST组较低,中位数为3分,FBP及L1BR组较高,中位数均为4分;DC评分L1BR、L2BR及L1BST组较高,中位数均为4分,L3BST组最低,中位数为3分.低剂量组图像中,LCD、ID评分分布与常规组相似,DC评分L1BST组最高(4分)而FBP组最低(2分).不同剂量组各重组图像的LCD、ID和DC评分差异均有统计学意义(P<0.05).常规组FBP图像的噪声为(9.8±2.0)HU,SNR为13.3±3.3,CNR为6.0±1.9;低剂量组FBP图像图像噪声、SNR和CNR分别为(16.2±4.1)HU、12.9±3.3和6.6±2.3.常规组随着IMR设置从L1BR到L3BST依次增高,图像噪声依次降低,从(4.5±0.9)HU降低到(3.2±0.2) HU,SNR及CNR则依次升高,SNR从21.4±1.4升高到24.6±4.6,CNR从9.4±2.2升高到10.9±2.9;低剂量组图像噪声、SNR及CNR的

英文摘要:

Objective To evaluate the effects of different reconstruction settings of knowledge-based iterative reconstruction technique (IMR) on noise reduction and image quality in hepatic contrast-enhanced CT(CECT) at different radiation dose levels.Methods Patients who underwent hepatic CECT because of their diseases were enrolled in this prospective study.According to random number table,patients were randomly assigned to two groups (standard dose group,SD-group,n=29; low dose group,LD-group,n=25).All patients underwent both non-enhanced CT and triphasic CECT scan including hepatic arterial phase (HAP),portal-venous phase (PVP) and delayed phase.PVP images of SD-group were acquired with tube voltage of 120 kVp and tube current-time products of 250 mAs,and 80 kVp and 500 mAs for LD-group.PVP images were reconstructed with both filtered back projection (FBP) and IMR techniques.Settings applied in IMR reconstructions consisted of body routine (BR) and body soft tissue (BST) with three levels (L1 to L3),and image series included:L1BR,L2BR,L3BR,L1BST,L2BST and L3BST.Subjective assessment of image quality including low contrast detectability (LCD),image distortion (ID) and diagnostic confidence (DC) as well as objective image quality including image noise,signal to noise ratio (SNR) and contrast to noise ratio (CNR) were compared between groups.Effective radiation dose was recorded.Objective image quality and subjective image quality were compared by using Friedman H test and ANOVA,respectively.In addition,Student t test was used to compare effective radiation doses between groups.Results In SD-group,IMR settings of L2BST,L3BST scored highest in LCD with median score of 4;L3BST and L2BST scored lowest in ID with median score of 3,while FBP and L1BR scored highest with median score of 4; L1BR,L2BR and L1BST scored highest in DC with median score of 4,while L3BST scored lowest with median score of 3.In LD-group,the distribution of all reconstruction settings scores in LC

同期刊论文项目
同项目期刊论文
期刊信息
  • 《中华放射学杂志》
  • 中国科技核心期刊
  • 主管单位:中国科协
  • 主办单位:中华医学会
  • 主编:
  • 地址:北京市东四西大街42号
  • 邮编:100710
  • 邮箱:cjr@cma.org.cn
  • 电话:010-85158384
  • 国际标准刊号:ISSN:1005-1201
  • 国内统一刊号:ISSN:11-2149/R
  • 邮发代号:2-66
  • 获奖情况:
  • 中华医学会2001年优秀期刊一等奖,1992年中国科协新闻出版署优秀学术期刊三等奖,199...,中国期刊方阵“双效”期刊
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),波兰哥白尼索引,荷兰文摘与引文数据库,荷兰医学文摘,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:64918