介绍了某电厂700MW机组现场选择性催化还原(selective catalytic reduction,SCR)脱硝系统考核试验,包括烟气温度分布测量、烟气流量测量、系统压损测量、烟气NOx、O2测量及脱硝效率计算、氨逃逸率(体积分数)测量、SO2/SO3转化率测量、氨耗量计算等,所得结果表明SCR脱硝系统满足SCR性能保证值要求,但是,现场性能试验还说明SCR脱硝系统还存在问题,需进一步解决并提出解决措施。
This paper introduces examination test for selective catalytic reduction denitration system of 700 MW unit of some power plant including flue gas temperature distribution measuring, flue gas flow measuring, measuring for loss of pressure of system, NOx and Oimeasuring, calculation on denitration efficiency, ammonia escape rate measuring, SO2/SO3 conversion percent measuring and calculation on ammonia consumption. Results indicated that SCR denitration system was able to meet requirement for SCR performance guarantee value, but there were still existing some problems in SCR denitration system to be solved and solutions were needed to be proposed.