差异旋风分离器并联性能测量及流场分析
  • ISSN号:0438-1157
  • 期刊名称:《化工学报》
  • 时间:0
  • 分类:TQ028.2[化学工程]
  • 作者机构:[1]中国石油大学北京重质油国家重点实验室,北京102200, [2]过程流体过滤与分离技术北京市重点实验室,北京102200
  • 相关基金:国家自然科学基金项目(21176249); 国家重点基础研究发展计划项目(2012CB215000).
中文摘要:

通过改变旋向和芯管直径,设计了3种差异旋风分离器,并按中心对称方式组成了3种并联方案:相同分离器、旋向差异分离器和芯管差异分离器并联。在冷态实验装置上,测量了单分离器和并联分离器的性能,并利用FLUENT软件分析了并联分离器的流场。结果表明,并联分离器的效率均高于单分离器,且效率-气速曲线未出现"驼峰";与相同分离器并联相比,旋向交替变化时并联总压降较小,分离效率也更低,但各分离器流量分配均匀,未发现"窜流"现象;当芯管有差异时,并联总压降增大,各分离器进口流量分配不均匀,且进、出口流量平均相差6.0%,公共灰斗中存在"窜流",旋流稳定性变差,效率降低。为了保证并联分离器的性能,应采用相同分离器对称并联的方式。

英文摘要:

Three different cyclone separators with diameter of 300 mm, PV-1, PV-2 and PV-3, were designed by changing either the direction of rotation or the diameter of vortex finder. PV-1 differed from PV-2 in the direction of rotation, while PV-3 differed from PV-1 in the diameter of vortex finder. These cyclone separators were assembled center-symmetrically in three paralleled arrangements as assembly of same cyclones(Parallel-Ⅰ), assembly of various rotation(Parallel-Ⅱ) and assembly of various vortex finder(Parallel-Ⅲ). Parallel-Ⅰ was consisted of four PV-1 cell cyclones; Parallel-Ⅱ was consisted of two PV-1 cyclones and two PV-2 cyclones; Parallel-Ⅲ was consisted of two PV-1 cyclones and two PV-3 cyclones. Separation performances of single cyclone and cyclone assemblies were studied in a cold state experimental setup under a condition of solid loading at 5 g·m^-3 and inlet velocities ranging from 14—26 m·s^-1. The flow fields in these paralleled cyclones were simulated with FLUENT software. The results show that paralleled cyclones had higher efficiency than single one with no hump in the curve of efficiency versus inlet velocity. Compared to Parallel-Ⅰ, Parallel-Ⅱ was lower in both total pressure drop and efficiency due to weaker swirl flow. Gas throughput was evenly distributed among each cell cyclone and no cross flow was observed in the common dust bin of either Parallel-I or Parallel-Ⅱ. However, Parallel-Ⅲ had higher total pressure drop than Parallel-Ⅰ. Because Parallel-Ⅲ was composed of cellcyclones with different vortex finder, gas throughput in Parallel-Ⅲ was no longer evenly distributed and an average deviation of about 6.0% was observed between the inlet and outlet of each cell cyclone. A cross flow in the common dust bin was also happened from PV-3 to PV-1, which forced some collected particles back to the inner flow, weakened the stability of vortex flow and decreased separation efficiency. Therefore, the same type of cyclone separators should be assembled center-s

同期刊论文项目
同项目期刊论文
期刊信息
  • 《化工学报》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国化工学会 化学工业出版社
  • 主编:李静海
  • 地址:北京市东城区青年湖南街13号
  • 邮编:100011
  • 邮箱:hgxb126@126.com
  • 电话:010-64519485
  • 国际标准刊号:ISSN:0438-1157
  • 国内统一刊号:ISSN:11-1946/TQ
  • 邮发代号:2-370
  • 获奖情况:
  • 中国科协优秀期刊二等奖,化工部科技进步二等奖,北京全优期刊奖,中国期刊方阵“双效”期刊,第三届中国出版政府奖
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:35185