位置:成果数据库 > 期刊 > 期刊详情页
快速去除硝酸和亚硝酸对氢化物发生原子荧光法测定砷的干扰
  • ISSN号:0253-3820
  • 期刊名称:《分析化学》
  • 时间:0
  • 分类:O614.433[理学—无机化学;理学—化学] S153.62[农业科学—土壤学;农业科学—农业基础科学]
  • 作者机构:[1]浙江大学化学系,杭州310027, [2]浙江省出入境检验检疫局,杭州310012
  • 相关基金:本文系国家自然科学基金(Nos.20775072,20675022)及浙江省自然科学基金(No.Z407029)资助项目
中文摘要:

为了避免繁琐、耗时的“赶酸”操作,研究了尿素结合NaOH除去微波消解液中过量的HNO3和HNO2的干扰,继用L-半胱氨酸在低酸度下将As(Ⅳ)还原为As(Ⅲ)的样品消化和预还原方法。用氢化物发生-原子荧光法准确、快速地测定了食品中痕量砷。该方法的检出限为0.03μg/L;连续11次测定4μg/LA(Ⅲ)标准溶液的相对标准偏差为1.6%;测定国家标准物质的结果与标准值非常吻合。

英文摘要:

Abstract To avoid time-consuming procedure for evporating excessive nitric acid added for microwave digestion and nitrite ion generated during digestion, a rapid pretreatment method was developed. After microwave digestion, the nitrite ion was removed by adding urea and the nitric acid was neutralized by sodium hydroxide. L-cysteine was used to prereduce As (Ⅴ) to As (Ⅲ) with hydrochloric acid in low concentration. The proposed pretreatment mothod was successfully applied to the determination of trace amount of arsenic in foods with hydride generation-atomic fluorescence spectrometry. The method is fast and can prevent sample contamination and loss. The detection limit was 0.03 μg/L. The relative standard deviation for 11 determinations of a solution containing 4 μg/L arsenic was 1.6%. Results obtained for both standard reference materials agreed well with the certified values with a good precision.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《分析化学》
  • 北大核心期刊(2011版)
  • 主管单位:中国科学院
  • 主办单位:中国化学会 中国科学院长春应用化学研究所
  • 主编:杨秀荣
  • 地址:长春市人民大街5625号
  • 邮编:130022
  • 邮箱:fxhx@ciac.ac.cn
  • 电话:0431-85262017
  • 国际标准刊号:ISSN:0253-3820
  • 国内统一刊号:ISSN:22-1125/O6
  • 邮发代号:12-6
  • 获奖情况:
  • 1999获首届国家期刊奖,2000年获中国科学院优秀期刊特别奖,2001年入选中国期刊方阵“双高”期刊
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国乌利希期刊指南,美国剑桥科学文摘,美国科学引文索引(扩展库),日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:52455