多普勒超声预测HIFU治疗子宫肌瘤早期疗效
  • ISSN号:1000-8179
  • 期刊名称:《中国肿瘤临床》
  • 时间:0
  • 分类:R737.3[医药卫生—肿瘤;医药卫生—临床医学] R445.1[医药卫生—影像医学与核医学;医药卫生—诊断学;医药卫生—临床医学]
  • 作者机构:[1]复旦大学附属上海市第五人民医院超声医学科,上海市200240, [2]重庆医科大学医学超声工程研究所
  • 相关基金:本文课题受国家自然科学基金资助(编号:30325027)
中文摘要:

目的:通过多普勒超声观察高强度聚焦超声(HIFU)治疗子宫肌瘤滋养血管血流动力学变化,探讨其在疗效评价方面的应用价值。方法:HIFU治疗子宫单发肌壁间肌瘤30例,分别于HIFU术前、术后即刻、1个月及3个月行超声检查,比较肌瘤周边滋养血管和子宫动脉PI及RI变化,并将术后3个月体积变化与其进行相关分析。结果:术后1月及3个月肌瘤体积分别由术前的(40.92±28.58)cm^2降至(27.48±16.92)cm^3(P〈0.001)和(15.57±17.72)cm^3(P〈0.0001),肌瘤HIFU术后即刻周边滋养血管RT增高(P〈0.05),术后3个月滋养血管RI较1个月增高(P〈0.01),术后1个月周边滋养血管PI增高(P〈0.05),HIFU术后即刻较术前,术后3个月较1个月子宫动脉RI增高(P〈0.001),PI增高不明显(P〉0.05)。子宫肌瘤HIFU术后1个月周边滋养血管RI增加率与术后3个月体积缩小率呈正相关(r=0.42),术后3个月周边滋养血管RI增加率与之呈正相关(r=0.33)。结论:多普勒超声检测HIFU术后1月肌瘤周边滋养血管RI是预测早期疗效的有效手段。

英文摘要:

Objective: To observe the hemodynamic changes in trophoblast vessels of uterine fibroids with the doppler ultrasound and to explore the practical value of doppler ultrasound in evaluating the efficacy of HIFU ablation therapy for uterine fibroids. Methods: Thirty patients with haplo-intramural fibroids, aged 29-48, were treated with HIFU. Doppler ultrasound was used to observe PI and RI changes of the uterine artery and trophoblast vessels of uterine fibroids before HIFU treatment, immediately after the treatment, 1 month after the treatment and 3 months after the treatment. Analyses were performed to compare the increase with the reduction of fibroid volume at 3 months after HIFU treatment. Results: At 1 month after HIFU treatment, the fibroid volume was reduced from 40.92±28.58cm^3 to 27.48±16.92cm^3 (P〈0.001). At 3 months after the treatment, the fibroid volume was reduced to 15.57±17.72cm^3 (P〈0.0001). Immediately after HIFU treatment, RI of the trophoblast vessels of uterine fibroids was increased (P〈0.05). At 3 months after the treatment, Rl of the trophoblast vessels of uterine fibroids was higher than that at 1 month after the treatment (P〈0.01). At 1 month after the treatment, PI of the trophoblast vessels of uterine fibroids was increased (P〈0.05). Immediately after the treatment, RI of the uterine artery was higher than that before the treatment. At 3 months after the treatment, RI of the uterine artery was higher than that at 1 month after the treatment (P〈0.001). PI of the uterine artery was increased inconspicuously. At 1 month after the HIFU treatment, the increasing rate of RI of the trophoblast vessels of uterine fibroids was positively correlated with the reduction ratio of the volume of artery (r=0.42). At 3 months after HIFU treatment, the increasing rate of RI of the trophoblast vessels of uterine fibroids was positively correlated with the reduction ratio of the volume of artery (r= 0.33). Conclusion: Doppler ultrasound is an effective w

同期刊论文项目
期刊论文 41 会议论文 6 获奖 1 著作 2
同项目期刊论文
期刊信息
  • 《中国肿瘤临床》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国抗癌协会
  • 主编:郝希山
  • 地址:天津市河西区体院北环湖西路天津肿瘤医院C楼3层
  • 邮编:300060
  • 邮箱:cjco@cjco.cn
  • 电话:022-23527053
  • 国际标准刊号:ISSN:1000-8179
  • 国内统一刊号:ISSN:12-1099/R
  • 邮发代号:6-18
  • 获奖情况:
  • 1997、1999、2001三次获中国科协优秀期刊奖励基金,2001年获天津市科技期刊一等奖,1996年获中国科协优秀期刊三等奖,2011年天津市优秀期刊提名奖,2011年中国精品科技期刊
  • 国内外数据库收录:
  • 美国化学文摘(网络版),波兰哥白尼索引,荷兰文摘与引文数据库,荷兰医学文摘,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:37940