建立了一种同时测定沉积物中不同赋存形态的多溴联苯醚(PBDEs)和四溴双酚A(TBBPA)的分析方法。样品由等体积的丙酮和正己烷混合溶剂抽提得到自由态目标物,再通过碱性水解反应释放束缚态目标化合物。通过调节酸度(pH值)实现PBDEs和TBBPA的分离和提取。PBDEs由复合硅胶柱净化,运用气相色谱-质谱(负离子化学源)-分时段选择离子监测技术测定;TBBPA经重氮甲烷衍生化反应后由酸性硅胶柱预纯化,运用气相色谱-质谱(电子轰击源)-分时段选择离子监测技术测定。8种低溴联苯醚(BDE28,-47,-66,-100,-99,-154,-153,-183),十溴联苯醚(BDE209)和TBBPA的检出限分别为0.6~12.5pg/g,172pg/g,4.2pg/g。方法具有良好的准确度和精确度,回收率均在74%~106%之间,RSD≤10%。对东江沉积物样品的分析表明,本方法能够实现不同形态的PBDEs和TBBPA的有效检测。
An analysis method was developed for the determination of free and bound fractions of polybrominated ethers (PBDEs) and tetrabromobisphenol A (TBBPA) in sediment. The free PBDE and TBBPA were extracted with acetone/hexane ( 1 : 1 ) mixed solvent, and the bound fraction was released from the sediment by saponification reaction at 80 ℃. PBDEs and TBBPA were separated via adjusting pH; PBDEs were determined by GC-negative chemical ionization (NCI)-MS after cleaned up by multilayer silica column, and TBB- PA was derivative before pre-separated by acid silica column and finally determined by GC-EI-MS. All of the target compounds were quantitative by internal standard method. The limits of detection of eight low brominated congeners (BDE28, -47, -66, -100, -99, -154, -153 and -183) , deca-BDE (BDE209), and TBBPA were 0.6 -12.5 pg/g, 172 pg/g and 4.2 pg/g,respectively; This method is reliable and stable. The recoveries of all compounds were ranged from 74% to 106% and the relative standard deviations were below 10%. This method is suitable for the measurement of different forms of PBDEs and TBBPA in sediment under reliable quality assurance and quality control.