本研究以硫堇聚合物作为内参比探针分子,通过电化学聚合法将硫堇聚合于单壁碳纳米管修饰玻碳电极(SWNTs/GCE)上,并以该修饰电极为工作电极,建立了一种比率型检测Cu^2+的电化学传感方法。结果表明,在1~25μmol/L浓度范围内,Cu^2+的阳极溶出峰电流ICu^2+与聚硫堇氧化峰电流ITh的比值与Cu^2+浓度呈较好的线性关系,检测限为96nmol/L,方法用于加标自来水样中Cu^2+的检测,回收率较好。
Thionine polymer(polythionine,poly-Th)was used as an internal reference probe,and was coated on a single-walled carbon nanotubes(SWNTs) modified glassy carbon electrode by electropolymerization method.As-fabricated modified electrode was used as the working electrode by anodic stripping voltammetry for the detection of copper ions,and a ratiometric electrochemical method was established for the determination of Cu^2+.The results indicated that under the optimum conditions in the Cu^2+concentration range 1-25μmol/L,the ratio of the anodic stripping peak current of Cu^2+(ICu^2+)and the oxidation peak current of poly-Th(ITh)was proportional to the concentration of Cu^2+with the detection limit of 96nmol/L.The method can be applied to the determination of Cu^2+in spiked tap water samples with good recovery,which establishes the foundation for fast,simple,accurate determination of Cu^2+using ratiometric electrochemical method.