位置:成果数据库 > 期刊 > 期刊详情页
用于铯原子内态操控的双光子拉曼激光的产生及应用
  • ISSN号:1000-3290
  • 期刊名称:《物理学报》
  • 时间:0
  • 分类:O629.1[理学—有机化学;理学—化学]
  • 作者机构:[1]山西大学光电研究所、量子光学与光量子器件国家重点实验室,太原030006
  • 相关基金:国家自然科学基金(批准号:11125418,91336107,61275210,61227902); 国家重点基础研究发展计划(批准号:2012CB921601)资助的课题
中文摘要:

双光子拉曼过程是一种有效制备和控制原子内态的方法,在原子内态操控和基于原子的量子信息处理中具有重要意义.研制用于特定原子的拉曼激光是实现该过程的重要一步.报道了利用光纤波导相位调制器及滤波器等实现用于铯原子内态操控的拉曼激光的方法,并成功用于单个铯原子的内态精密操控.通过4.6 GHz的微波信号源直接驱动波导相位调制器高效地获得光场的调制边带,并利用自由光谱区为9.19 GHz的法布里-珀罗腔将载波及二阶边带滤掉,获得了频率精确、相差9.19 GHz的拉曼激光.经过基于光纤振幅调制器的功率稳定系统,最终可以获得总功率为73μW、长时间内波动为2.2%的拉曼激光束,并将此光束用于激发单个铯原子,实现了|6S(1/2),F=4,mF=0〉和|6S(1/2),F=3,mF=0〉之间的可控拉比操作.

英文摘要:

Two-photon Raman process(TPRP) is an important technique in controlling the atomic internal states.It plays an important role in quantum manipulation and quantum information process.A reliable Raman laser for specific atom is the first step to demonstrate TPRP and quantum manipulation of an atom.In this paper,we theoretically analyze the two-photon Raman process regarding to Cesium "clock states" |6S(1/2),F = 4,mF = 0 and |6S(1/2),F = 3,mF = 0,and we obtain the dependences of the corresponding Rabi frequency on one- and two-photon detunings and one-photon Rabi frequencies in a realistic multi-level Cesium atom system.We find that to obtain an atom state flopping efficiency of 0.99 the Raman laser power fluctuation should be controlled to be smaller than 3.2%.We also report our simple experimental Raman laser system for TPRP of Cesium atom based on a fiber waveguide phase modulator.The phase modulator is driven by a 4.6 GHz microwave source and the two first-order sidebands with a frequency difference of 9.19 GHz are filtered out by a Fabry-Perot cavity with a finesse of 48.After an amplitude-modulator-based intensity stabilization system,a total power of 73 μW with a fluctuation of 2.2%within 90 min is obtained.By applying this Raman laser to a single Cesium atom trapped in a micrometer size far-off resonant trap(FORT),we obtain Raman spectra between Cesium "clock states" |6S(1/2),F = 4,mF = 0 and |6S(1/2),F = 3,mF = 0.The discrepancy between the two-photon resonance frequency and the defined clock frequency 9.192631770 GHz is due to the differential Stark shifts by FORT beam and Raman beams as well as the inaccuracy of the microwave source.By varying the Raman pulse length we also show the corresponding Rabi flopping with a rate of 153 kHz,which is consistent with the theoretical calculation.The obtained state transfer efficiency of 0.75 is much smaller than theoretical expectation 0.99,which is mainly limited by the state initialization efficiency.The Raman laser system

同期刊论文项目
期刊论文 58 会议论文 1
同项目期刊论文
期刊信息
  • 《物理学报》
  • 北大核心期刊(2011版)
  • 主管单位:中国科学院
  • 主办单位:中国物理学会 中国科学院物理研究所
  • 主编:欧阳钟灿
  • 地址:北京603信箱(中国科学院物理研究所)
  • 邮编:100190
  • 邮箱:apsoffice@iphy.ac.cn
  • 电话:010-82649026
  • 国际标准刊号:ISSN:1000-3290
  • 国内统一刊号:ISSN:11-1958/O4
  • 邮发代号:2-425
  • 获奖情况:
  • 1999年首届国家期刊奖,2000年中科院优秀期刊特等奖,2001年科技期刊最高方阵队双高期刊居中国期刊第12位
  • 国内外数据库收录:
  • 美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国科学引文索引(扩展库),英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),中国北大核心期刊(2000版)
  • 被引量:49876