位置:成果数据库 > 期刊 > 期刊详情页
基因测序技术及其临床应用
  • ISSN号:1674-1358
  • 期刊名称:《中华实验和临床感染病杂志(电子版)》
  • 时间:0
  • 分类:R446.5[医药卫生—诊断学;医药卫生—临床医学]
  • 作者机构:[1]泗阳县人民医院检验科,江苏泗阳223700, [2]南京医科大学第一附属医院检验学部,南京210029
  • 相关基金:国家自然科学基金(81000754,81471994).
中文摘要:

目的:了解不同送检模式的血培养阳性率与病原菌的分布状况。方法:采用BD FX400全自动血培养仪对2013年全年送检的血液标本进行培养,阳性标本做病原菌鉴定,对不同送检模式血培养阳性率与病原菌进行分析。结果:5.565份血培养标本,培养出687株病原菌,阳性率为12.3%(687/5 565);其中双侧双瓶血培养送检率为87.6%(4 875/5 565),阳性率为12.8%(624/4 875),明显高于单侧单瓶的阳性率9.0%(30/335)(χ^2=0.0025,P〈0.005)及双侧单瓶的阳性率9.3%(33/355),但与后者比较无统计学意义。双侧双瓶和双侧单瓶血培养病原菌检出率最高的均为大肠埃希菌,分别为27.6%(172/624)和30.3%(10/33);而单侧单瓶血培养病原菌检出率最高的则为凝固酶阴性的葡萄球菌,占40%(12/30),此菌在双侧双瓶和双侧单瓶病原菌中各占12.8%(80/624)和18.2%(6133)。在双侧双瓶标本分离的624株病原菌中,有了7株仅在厌氧瓶中生长,占血培养总菌株11.2%(77/687)。结论:双侧双瓶血培养送检模式提高了血培养阳性率,降低了漏检率,有利于提高血培养检验质量。

英文摘要:

Objective: To understand the effect of different submission methods on blood culture positive rate and the distribution of pathogens. Methods: Blood culture of blood specimens submitted in 2013 was performed with BD FX400 automated blood cttlture system. Characterization of pathogens was further performed for positive specimens. Blood culture positive rate and the distribution of pathogens with different submission methods were analyzed. Results: A total of 687 pathogens were found from 5 565 blood specimens with a positive rate of 12.3% (687/5 565), where bilateral double bottles submission accounted for 87.6% (4 875/5 565) with a positive rate of 12.8% (624/4 875). The positive rate of blood culture with bilateral double bottles was significantly higher than that with unilateral single bottle of 9.0% (30/335) (~=0.0025, P〈0.005) and that with bilateral single bottle of 9.3% (33/355). However, there was no statistical difference in positive rate between bilateral double bottles and bilateral single bottle. Escherichia coli was the pathogen with the highest detection rate, which was 27.6% (172/624) and 30.3% (10/33) for bilateral double bottles and bilateral single bottle, respectively. With regard to unilateral single bottle, coagulase-negative staphylococci were the mostly detected pathogen, accounting for 40% (12/30). The detection rate of coagulase-negative staphylococci in blood cultures with bilateral double bottles and bilateral single bottles were 12.8% (80/624) and 18.2% (6/33), respectively. Among the 624 pathogens isolated with bilateral double bottle specimens, 77 could only grow in anaerobic conditions, accounting for 11.2% of blood culture isolates total (77/687). Conclusion: Bilateral double bottle submission methods can increase blood culture positive rate with a decrease in undetected rate, which will help to improve the quality of blood culture tests.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《中华实验和临床感染病杂志(电子版)》
  • 中国科技核心期刊
  • 主管单位:中华人民共和国卫生和计划生育委员会
  • 主办单位:中华医学会
  • 主编:
  • 地址:北京朝阳区京顺东街8号北京地坛医院
  • 邮编:100015
  • 邮箱:editordt@163.com
  • 电话:010-84322058
  • 国际标准刊号:ISSN:1674-1358
  • 国内统一刊号:ISSN:11-9284/R
  • 邮发代号:
  • 获奖情况:
  • 国内外数据库收录:
  • 美国化学文摘(网络版),中国中国科技核心期刊
  • 被引量:4609