用阳离子交换树脂CM-52分离纯化类人胶原蛋白Ⅱ(Human Collagen-like Bioprotein Ⅱ,HCBⅡ)。通过实验,分别确定了静态吸附和柱层析吸附的操作条件,即静态吸附:在pH4.0、NaCl0.15mol/L、进料浓度7g/L,处理量17.26ml/g树脂的条件下进行吸附,吸附时间为60min;柱层析:在pH4.0、NaCl0.15mol/L、进料浓度5g/L、流速5ml/min的条件下进行吸附。然后上柱,在pH4.0、NaCl0.30mol/L下进行脱附。实验表明,采用静态吸附的方式吸附HCBⅡ,然后上柱洗脱,HCBⅡ的吸附量可达到48、6mg/g树脂,回收率83.8%,操作时间短,分辨率高,最终纯化的HCBⅡ达电泳纯,分子量为97kD。
A purification method of recombinant human collagen-like Bioprotein Ⅱ (HCB Ⅱ) by the CM52 cation exchange chromatography were reported. The batch operation and normal chromatography column method were used in experiments, i.e., Batch operation of chromatography: HCB Ⅱ was absorbed under pH 4.0, NaCl (ionic strength) 0.15mol/L, 17.26ml (protein volume)/g (resin) and concentration of crude protein liquid 7g/L; Column chromatography: HCB Ⅱ was absorbed under pH 4.0, NaCl (ionic strength) 0.15mol/L, flow rate 5ml/min and concentration of crude protein liquid 5g/L, the elution of HCB Ⅱ was pH 4.0, the concentration of NaCl (ionic strength) 0.30mol/L. As a result, the CM52 cation exchange chromatography was of better capacity of adsorption for HCB Ⅱ and the elution was simple; the total purity process time would be shorten and resolution was high, The recovery of aim protein HCB Ⅱ with a molecular weight around 97kD was above 83.8% and purity of HCB Ⅱ could reach electrophoresis grade purity.