中文摘要:

研究大长径比柔性线缆的运动轨迹测量.根据线缆的几何特征和运动特点,提出了一种基于中心线匹配法的双目视觉运动检测方法,分析了该方法测量流程中的标定、匹配和重构误差之间的关系,建立了测量系统的几何误差模型并推导了误差估算公式,同时设计了一种误差校核方法.对该方法进行了实验验证,结果表明误差估计值0.11mm与实测误差值0.09mm接近,满足工程要求.

英文摘要:

In order to detect the trace of flexible movable cable harness accurately, a binocular vision measurement approach is proposed using centerline matching method according to the geometry feature of cable harness and the way of its motion-deformation-coupling. The relationships among calibration, matching and reconstruction error in the course of measurement were investigated. Then, a geometrical error model was set up and the error-estimate formula was deduced. Experiment has been conducted to proofread the measurement error. The result shows that the tested error is 0.09 mm, which comes close to the 0.11 mm value calculated by the formula, that indicate the presented error model is reality and the motion detection result could meet the engineering requirement.

同期刊论文项目
期刊论文 35 会议论文 2 获奖 1 专利 4
同项目期刊论文
期刊信息
  • 《北京理工大学学报》
  • 北大核心期刊(2011版)
  • 主管单位:中华人民共和国工业和信息化部
  • 主办单位:北京理工大学
  • 主编:黄风雷
  • 地址:北京海淀区中关村南大街5号
  • 邮编:100081
  • 邮箱:blgzw@bit.edu.cn
  • 电话:010-68912326 68913988
  • 国际标准刊号:ISSN:1001-0645
  • 国内统一刊号:ISSN:11-2596/T
  • 邮发代号:82-502
  • 获奖情况:
  • 全国优秀高等学校自然科学学报及教育部优秀科技期...,首届国家期刊奖提名奖,中文核心期刊
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),美国数学评论(网络版),德国数学文摘,荷兰文摘与引文数据库,美国工程索引,美国剑桥科学文摘,英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:17163