位置:成果数据库 > 期刊 > 期刊详情页
氯化铜掺杂的多壁碳纳米管对甲醛的气敏响应研究
  • ISSN号:1004-1699
  • 期刊名称:《传感技术学报》
  • 时间:0
  • 分类:TP212.2[自动化与计算机技术—控制科学与工程;自动化与计算机技术—检测技术与自动化装置]
  • 作者机构:[1]浙江大学生物医学工程与仪器学院,杭州310027, [2]浙江大学材化学院,杭州310027
  • 相关基金:国家863项目资助(2003AA404180);国家自然科学基金资助(30470461);浙江省自然科学基金资助(Y104406)
中文摘要:

按照一定的质量比将CuCl2与多壁碳纳米管悬浊液超声掺杂。将纯的多壁碳纳米管悬浊液和掺杂后的碳管悬浊液分别旋涂在真空溅射的叉指金电极上,干燥后作为气敏膜。分别检测两组气敏膜暴露于甲醛气体前后的电流变化,并计算其灵敏度。掺杂后的多壁碳管气敏膜的灵敏度显著提高,且响应与恢复时间均明显缩短;室温下该传感器的响应非常稳定。CuCl2掺杂所导致的多壁碳管结构缺陷的增加可能是提高掺杂后碳管气敏响应的重要因素。

英文摘要:

Multi-walled carbon nanotubes (MWCNTs) in water solution were doped with CuCl2 and sonicated for 24h. The doped MWCNTs solution and the purified MWCNTs solution were drop-deposited onto the interdigitated Au electrodes to make sensors respectively. Currents of the two sensors were detected when exposed to formaldehyde of different concentration. The sensitivity of the doped MWCNTs was found to improve dramatically and its response time and recovery time were shortened remarkably. Steady response was also observed at room temperature (288-308K). Structure defects of MWCNTs introduced by CuCl2-dopin.g process were thought to be the possible factor leading to the enhanced sensing reaction of doped MWCNTs.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《传感技术学报》
  • 北大核心期刊(2011版)
  • 主管单位:国家教育部
  • 主办单位:东南大学 中国微米纳米技术学会
  • 主编:黄庆安
  • 地址:南京市四牌楼2号
  • 邮编:210096
  • 邮箱:dzcg-bjb@163.com
  • 电话:025-83794925
  • 国际标准刊号:ISSN:1004-1699
  • 国内统一刊号:ISSN:32-1322/TN
  • 邮发代号:28-366
  • 获奖情况:
  • 2011-2012年获中国科技论文在线优秀期刊一等奖,2012年获第四届中国高校优秀科技期刊奖,2011年获中国精品科技期刊
  • 国内外数据库收录:
  • 美国化学文摘(网络版),荷兰文摘与引文数据库,英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版)
  • 被引量:18030