应用浮动基准法修正光谱光源漂移影响的模拟验证
  • ISSN号:1000-0593
  • 期刊名称:《光谱学与光谱分析》
  • 时间:0
  • 分类:O433.4[机械工程—光学工程;理学—光学;理学—物理]
  • 作者机构:[1]天津大学精密测试技术及仪器国家重点实验室,天津300072
  • 相关基金:国家自然科学基金项目(60938002); 国家(863计划)项目(2012AA022602); 中国博士后科学基金项目(2013M541174)资助
中文摘要:

近红外无创伤血糖检测目前面临的挑战主要是测量条件难以保证稳定、测量系统及被测对象自身的背景变化等问题,导致很难从背景变动的光谱中提取出糖浓度变化信息。经过多年的实验研究发现应用浮动基准参考测量法有望消除仪器漂移及被测对象自身背景变动的影响。但是浮动基准位置因人及测量部位不同而异,在不同的测量波长下其浮动基准点位置也不同,因此,欲在实验中验证浮动基准法的光谱修正效果需要测量出与入射光位置不同径向距离处的漫反射光强,然而在实际实验中位置精度很难保证。为此,研究了用模拟实验的方法验证多波长下浮动基准法对光源漂移所引起的光谱变化的修正效果,基于Monte Carlo模拟,分别采用浓度为5%和10%的Intralipid溶液作为被测样品,通过改变入射光子数模拟光源漂移的影响。得到模拟的光谱数据后,利用浮动基准法对其进行处理,并分别对浮动基准法修正前后的光谱数据进行偏最小二乘建模分析,将预测结果进行比较发现:两种浓度Intralipid溶液在存在光源漂移影响情况下修正后的模型预测精度预测均方根误差(RMSEP)相比于修正前分别减小了98.57%(5%Intralipid)和99.36%(10% Intralipid)。表明浮动基准法在消除光源漂移的影响方面效果明显。

英文摘要:

There are some challenges in near-infrared non-invasive blood glucose measurement, such as the low signal to noise ra- tio of instrument, the unstable measurement conditions, the unpredictable and irregular changes of the measured object, and etc. Therefore, it is difficult to extract the information of blood glucose concentrations from the complicated signals aeeurately. Ref- erence measurement method is usually considered to be used to eliminate the effect of background changes. But there is no refer- ence substance which changes synchronously with the anylate. After many years of research, our research group has proposed the floating reference method, which is succeeded in eliminating the spectral effects induced by the instrument drifts and the measured object's background variations. But our studies indicate that the reference-point will changes following the changing of measurement loeation and wavelength. Therefore, the effects of floating reference method should be verified comprehensively. In this paper, keeping things simple, the Monte Carlo simulation employing Intralipid solution with the concentrations of 5 % and 10% is performed to verify the effect of floating reference method used into eliminating the consequences of the light source drift. And the light source drift is introduced through varying the incident photon number. The effectiveness of the floating reference method with corresponding reference-points at different wavelengths in eliminating the variations of the light source drift is esti- mated. The comparison of the prediction abilities of the calibration models with and without using this method shows that the RMSEPs of the method are decreased by about 98. 57 % (5%Intralipid)and 99.36% (10%Intralipid)for different Intralipid. The results indicate that the floating reference method has obvious effect in eliminating the background changes.

同期刊论文项目
期刊论文 64 会议论文 17 专利 15 著作 1
同项目期刊论文
期刊信息
  • 《光谱学与光谱分析》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国光学学会
  • 主编:高松
  • 地址:北京海淀区魏公村学院南路76号
  • 邮编:100081
  • 邮箱:chngpxygpfx@vip.sina.com
  • 电话:010-62181070
  • 国际标准刊号:ISSN:1000-0593
  • 国内统一刊号:ISSN:11-2200/O4
  • 邮发代号:82-68
  • 获奖情况:
  • 1992年北京出版局编辑质量奖,1996年中国科协优秀科技期刊奖,1997-2000获中国科协择优支持基础性高科技学术期刊奖
  • 国内外数据库收录:
  • 俄罗斯文摘杂志,美国化学文摘(网络版),荷兰文摘与引文数据库,美国工程索引,美国生物医学检索系统,美国科学引文索引(扩展库),英国科学文摘数据库,日本日本科学技术振兴机构数据库,中国中国科技核心期刊,中国北大核心期刊(2004版),中国北大核心期刊(2008版),中国北大核心期刊(2011版),中国北大核心期刊(2014版),英国英国皇家化学学会文摘,中国北大核心期刊(2000版)
  • 被引量:40642