位置:成果数据库 > 期刊 > 期刊详情页
牙体牙髓治疗材料对牙本质抗折性能的影响
  • ISSN号:1001-165X
  • 期刊名称:《中国临床解剖学杂志》
  • 时间:0
  • 分类:R318.01[医药卫生—生物医学工程;医药卫生—基础医学] R781.05[医药卫生—口腔医学;医药卫生—临床医学]
  • 作者机构:[1]南方医科大学解剖学教研室广东省医学生物力学重点实验室,广州510515, [2]南方医科大学南方医院口腔医院,广州510515, [3]南方医科大学珠江医院口腔科,广州510282
  • 相关基金:国家自然基金重大项目(61190120,61190122,61190123)
中文摘要:

目的探究Biodentine和MTA对牙本质抗折性能的影响。方法选40颗中华田园犬尖牙,截冠、去除牙骨质并截去根尖,随机等分为5组。分别在根管内充填不同药物,3个月后行力学测试,得到标本3点弯曲强度和弯曲模量。结果各组标本3点弯曲强度分别:(154.77±16.51)MPa;(125.00±15.72)MPa;(140.81±11.99)MPa;(139.26±16.09)MPa;(120.17±14.21)MPa,单因素方差分析,F=6.74(P〈0.05)。各组标本弯曲模量分别为:(19.50±1.03)GPa;(9.62±1.34)GPa;(17.08±1.14)GPa;(15.73±2.14)GPa;(7.63±1.11)GPa;单因素方差分析,F=102.94(P〈0.05)。Biodentine和MTA对牙本质抗折性能的影响无统计学差异;与阳性对照组相比,Biodentine和MTA并不能提高牙本质抗折性能;与空白对照组和Vitapex相比,Biodentine和MTA能明显增加牙本质抗折性能。结论作为新兴生物性牙本质替代材料,与传统硅酸钙盐材料MTA相比,Biodentine在提高无髓牙牙本质抗折性能方面,并不具备明显优势。

英文摘要:

Objective To investigate the effect of Biodentine and MTA on the dentin's fracture resistance. Methods 40 fresh extracted Chinese rural dogs' canines were collected and randomly divided into 5 groups. The crowns and the cementum of the teeth were dissected. Each tooth was prepared with unity sample at the length of about 25 mm. Five groups' samples were filled with different medicines. The threepoint flexural strength and flexural modulus of the experimental specimens were determined by applying a vertical splitting load through a specially shaped steel rod. The maximum load value of root fracture was tested after three months. Results The average three-point flexural strength of the five groups was sequentially:(154.77 ± 16.51) MPa;(125.00 ± 15.72) MPa;(140.81 ± 11.99) MPa;(139.26 ± 16.09) MPa;(120.17±14.21) MPa. The average three-point flexural strength of the five groups were in order:(19.50±1.03)GPa;(9.62±1.34) GPa;(17.08±1.14)GPa;(15.73±2.14) GPa;(15.73±2.14) GPa;(7.63±1.11) GPa. The data were analyzed by one way ANOVA and LSD method(P〈0.05). The risk of pulpless root fracture may increase obviously as time goes by. The differences of the effect of Biodentine and MTA on the dentin's fracture resistance remains no statistically significant. Compared with the positive control group, MTA and Biodentine did not increase or restore the fracture resistance of dentin. But compared with the negative control group and Vitapex, Biodentine and MTA could significantly increase the fracture resistance of dentin. Conclusion As a new biological dentin substitute materials, compared with the traditional calcium silicate material-MTA,Biodentine did not have the obvious advantage in improving the flexural properties of dentine.

同期刊论文项目
同项目期刊论文
期刊信息
  • 《中国临床解剖学杂志》
  • 中国科技核心期刊
  • 主管单位:中国科学技术协会
  • 主办单位:中国解剖学会
  • 主编:欧阳均
  • 地址:广州市沙太南路1023号南方医科大学解剖学教研室
  • 邮编:510515
  • 邮箱:chjcana@126.com
  • 电话:020-61648203
  • 国际标准刊号:ISSN:1001-165X
  • 国内统一刊号:ISSN:44-1153/R
  • 邮发代号:46-108
  • 获奖情况:
  • 国内外数据库收录:
  • 被引量:19213